6 / 10 page ![]() Temperature Controller E5CS--X A--151 Precautions The E5CS-X temperature controller has self-diagnostic functions that display the following error messages to simplify troubleshooting. Message Cause Control output fff (1) Temperature has risen beyond temperature scale range (2) Thermistor has been short-circuited OFF during heating (reverse) operation ON during cooling (normal) operation --- (1) Temperature has fallen below temperature scale range (2) Thermistor has broken ON during heating (reverse) operation OFF during cooling (normal) operation fff (blinks)* (1) Failure has occurred in thermocouple or platinum RTD (2) Temperature has risen much beyond scale range OFF --- (blinks)* (1) Failure has occurred in platinum RTD (2) Polarities (positive and negative) of thermocouple are reversed (3) Temperature has fallen much below scale range OFF e11 or e33* (1) Memory failure (E11) display (2) Analog-to-digital converter failure (E33) display Temperature controller must be repaired if recovery is not made by turning power off once and on again. Both control outputs and the alarm output are OFF Note: *Key operations are disabled. When the alarm outputs are used, an alarm output occurs when the “FFF” and “------” messages appear in the display. These dis- plays indicate when the temperature has risen beyond or fallen below the temperature scale range. J Sensor Failure Indication Condition Display Control output Thermocouple sensor Break in sensor fff blinks OFF Short-circuit Ambient temperature OFF Platinum RTD sensor Break in sensor fff blinks OFF --- blinks OFF Disconnection of two or three wires fff blinks OFF Short-circuit --- blinks OFF Thermistor sensor Break in sensor --- ON during heating (reverse) action OFF during cooling (normal) action Short-circuit fff ON during heating (reverse) action OFF during cooling (normal) action Note: The resistance of the platinum RTD is 100 Ω at 0°C and increases to 140 Ω at 100°C. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |