| 数据搜索系统,热门电子元器件搜索 |
|
MP3360 数据表(PDF) 7 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP3360 数据表(HTML) 7 Page - Monolithic Power Systems |
|
7 / 8 page ![]() MP3360 – HIGHLY INTEGRATED PHOTO FLASH CHARGER AND IGBT DRIVER MP3360 Rev. 0.9 www.MonolithicPower.com 7 1/29/2010 MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited. © 2010 MPS. All Rights Reserved. OPERATION The MP3360 controlled flyback charger operates in critical conduction mode with peak current set by the CHG pin. The output voltage is divided down through internal 300: 1 resistive divider from the positive terminal of the transformer secondary (FB pin) and compares it with the internal 1.2V reference. The low to high transition of the CHG pin will enable the flyback converter to switch. A constant TOFF of 20µs is used when the output voltage is below 20V to avoid inrush current. The boundary mode operation will follow to minimize charge time when the output voltage is above 20V. A minimum TOFF of 200ns serves as blanking for turn off transition. The circuit will stop switching and RDYB will be pulled low once the flash capacitor is charged to 300V, a value set by the internal 300:1 R divider and 1.2V reference. VIGBT will be regulated to 2.7V. When the charge is full, then part will shut down its internal circuitry with less than 1uA drawn from VIN. Toggling the CHG pin will restart charge cycle. Bringing the CHG pin low terminates the power delivery and put the part in shutdown. A maximum TON timer prevents pulling current from a depleted battery. If the ON time exceeds maximum TON, the switch is forced OFF regardless of the IPEAK detection. CURRENT LIMIT PROGRAMMING The current limit can be programmed using the CHG pin. After asserting the CHG, it should be held high for at least 30us. After that, it takes two pulses to enter the programming mode. In the programming mode, each pulse advances the internal counter to the next higher current limit by 50mA until 750mA is reached and by 100mA increments beyond 750mA. The first pulse is for 400mA current limit. The next pulse will set the current limit to 450mA, etc. This programming should be done within 60us. Otherwise, the programming pulses will be ignored after the programming window expires. When you have advanced to the desired current limit setting, the high state should be held to make the part switch with the set current limit. To set the current limit to 1.5A (highest possible), the previous procedure is not necessary. Asserting and holding high the CHG pin will make the part switches with a 1.5A current limit. See the following timing diagram for detailed timing information. CHG tHI tEN-delay tLO tPW ON (Internal) ENPRG (Internal) First Two required to initiate programming Falling edge of the following pulses advance the internal counter During this time, the low state of CHG can not shut-down the part. Switching starts. ILIM Programming Timing Diagram (600mA Current Limit) 400mA 600mA |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |