| 数据搜索系统,热门电子元器件搜索 |
|
MP28248GD 数据表(PDF) 14 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP28248GD 数据表(HTML) 14 Page - Monolithic Power Systems |
|
14 / 19 page ![]() MP28248 – 3A, 3.3V-20V INPUT, FAST TRANSIENT SYNCHRONOUS STEP-DOWN CONVERTER IN 2X3MM QFN MP28248 Rev. 1.0 www.MonolithicPower.com 14 1/5/2012 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2012 MPS. All Rights Reserved. SS SS SS REF tms I A CnF VV (11) If the output capacitors are large, avoid setting a short SS time to avoid hitting the current limit during SS. Table 1 lists SS times with different external capacitor value. Table 1: Soft-Start Time vs. Capacitor Value tSS(ms) CSS(nF) 0.58 10 1.92 33 2.74 47 3.96 68 5.82 100 Over-Current Protection and Short-Circuit Protection The MP28248 has cycle-by-cycle over-current limit control that monitors the inductor current during the HS-FET ON state. Once the inductor current exceeds the current limit, the HS-FET turns off. At the same time, the OCP timer—set at 50µs—starts. OCP will trigger if the current reaches or exceeds the current limit every cycle during those 50µs, and the MP28248 enters hiccup mode to periodically restart the part. If VFB < 0.5xVREF and the current hits its limit, the MP28248 triggers the short-circuit protection (SCP) immediately and the MP28248 enters hiccup mode to periodically restart the part. If VFB < 0.5xVREF and the inductor current peak value exceeds the set current limit threshold, MP28248 enters hiccup mode to periodically restart the part. This protection mode is especially useful when the output shorts to ground, greatly reducing the average short-circuit current and any thermal build-up to protect the regulator. The MP28248 exits the hiccup mode once the over current condition is removed. Over-Voltage Protection (OVP) MP28248 monitors the output voltage through the tap of a resistor divider connected to FB. When VFB exceeds 1.25xVREF, MP28248 triggers OVP. LS-FET is then left on, while the HS-FET is off. Exiting OVP requires power cycling the MP28248. UVLO protection MP28248 has UVLO protection. When VIN exceeds the UVLO rising threshold voltage, the chip powers up. It shuts off when VIN is less than the UVLO falling threshold voltage. This is non- latch protection. Thermal Shutdown The junction temperature of the IC is monitored internally. If the junction temperature exceeds the threshold value (typically 150°C), the converter shuts off. This is non-latch protection. There is about 25°C hysteresis. Once the junction temperature drops to around 125°C, it initiates a soft start. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |