| 数据搜索系统,热门电子元器件搜索 |
|
AM79C982 数据表(PDF) 21 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C982 数据表(HTML) 21 Page - Advanced Micro Devices |
|
21 / 26 page ![]() AMD PRELIMINARY 1–23 Am79C982 Minimum Mode The Minimum Mode reconfigures the bIMR device Man- agement Port and is intended to provide support for the low end, non-managed repeaters, requiring minimal ex- ternal logic to provide LED indication of: s Twisted Pair Ports Link Status indication and AUI Loopback Status s Port Partitioning Status s Twisted Pair Ports Receiver Polarity Status and AUI SQE Test Error Status s Port Bit Rate Error Status The Minimum Mode is selected by controlling the state of the TEST pin while RST is asserted. If TEST is High (asserted), while reset is active ( RST LOW), then Mini- mum Mode is selected. The state of SI pin, at the de- assertion of the RST signal, determines whether the bIMR chip is to be programmed for Automatic Polarity Detection/Correction. When entering the Minimum Mode, the TEST input has to be deasserted on the rising edge of reset. A maximum delay of 100 ns is allowed to account for slow devices. The following table summarizes the different modes available. Test SI Functions 0 0 Normal Management Mode 0 1 Normal Management Mode 1 0 Minimum Mode, Receive Polarity Correction disabled 1 1 Minimum Mode, Receive Polarity Correction enabled In Minimum Mode, the SO pin is used to serially output the various status information based on the state of the SI and SCLK pins. A summary of the status information is provided in the following table. SCLK SI SO Output 0 0 TP Ports Receive Polarity Status + AUI SQE Test Error Status. 0 1 Bit Rate Error (all ports). 1 0 TP Ports Link Status + AUI LoopBack Status 1 1 Port Partitioning Status (all ports) When SI = 0 then SO will output the related AUI status bits (LoopBack or SQE), followed by the 8 (4) TP status bits (Link or Polarity), starting with the TP port 0. When SI = 1, the Port Partitioning Status or Port Bit Rate Error Status are scanned out with the AUI first and TP ports following. TP Port 0 is scanned out first. Note that the Bit Rate Error, AUI Loopback, and AUI SQE Test Error status bits stay set until they are scanned out. The state of SI and SCLK inputs is checked at the end of every STR cycle. The rising edge of the X1 clock, occur- ring before falling edge of STR, is used to strobe in the state of the SI and SCLK pins. In this Minimum Mode, the Management Port mode is not active. To exit the Minimum mode, the bIMR device must reset into the normal Management Port mode. Am79C982 bIMR8 Chip XTAL OSC CK D Q ASYNC RESET X1 X2 RST STR SO CLR CK Q Q D 1/2 ’74 TCK CK SI SIPO CK T P 7 T P 6 T P 5 T P 0 A U I 1/2 ’74 TCK SCLK SI 19406B-10 Register TEST Figure 3. bIMR8 LED Display Design using Minimum Mode |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |