41 / 56 page ![]() L6717 Output voltage monitoring and protections Doc ID 17326 Rev 1 41/56 8 Output voltage monitoring and protections L6717 monitors the regulated voltage of both sections through pin VSEN and NB_VSEN in order to manage OV, UV and PWRGOOD. The device shows different thresholds when in different operative conditions but the behavior in response to a protection event is still the same as described below. Protections are active also during soft-start (See Section 7.8) while they are masked during OTF-VID transitions with an additional delay to avoid false triggering. Table 20. L6717 protection at a glance 8.1 Programmable overvoltage (I2DIS = 3.3 V) When power manager I2C is disabled, L6717 provides the possibility to adjust OV threshold (common for both sections) through the SDA/OVP pin. Connecting the pin to the center tap of a voltage divider from 3.3 V to SGND, the OVP threshold becomes the voltage present at the pin. The OVP threshold results: L6717 Section CORE North bridge Overvoltage (OV) SVI / PVI: +250mV above reference, programmable by power manager I2C bus. I2CDIS = 3.3V: Programmable through SDA/OVP pin. V_FIX: Fixed to 1.8V. Action: IC Latch; LS=ON & PWMx = 0 (if applicable); Other section (SVI only): HiZ; FLT driven high. Undervoltage (UV) VSEN, NB_VSEN = VID -400mV. Active after Ref > 500mV Action: IC latch; both sections HiZ; FLT driven high. PWRGOOD PWRGOOD is the logic AND between internal CORE and NB PGOOD in SVI mode while is the CORE section PGOOD in PVI mode. Each PGOOD is set to zero when the related voltage falls below the programmed reference -250mV. Action: Section(s) continue switching, PWRGOOD driven low. VSEN, NB_VSEN disconnection Set when VSEN > CS1N +600mV. Action: UV-Like Set when VSEN > NB_CSN +600mV. Action: UV-Like (SVI only) FBG, NB_FBG disconnection Internal comparator across the opamp to recover from GND losses. Action: UV-Like Over Current (OC) Current monitor across inductor DCR. Dual protection, per-phase and average. Action: UV-Like Current monitor across inductor DCR. Constant current. Action: UV-Like On-the-fly VID Protections masked with the exception of OC with additional 16 clock delay to prevent from false triggering (both SVI and PVI). OVP TH 3.3 R OVPL R OVPH R + OVPL ------------------------------------------- ⋅ = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |