| 数据搜索系统,热门电子元器件搜索 |
|
LBA120LS 数据表(PDF) 3 Page - Clare, Inc. |
|
|
|||||||||||||||||||||||||||||
LBA120LS 数据表(HTML) 3 Page - Clare, Inc. |
|
3 / 8 page ![]() LBA120L www.clare.com Rev. 3 PERFORMANCE DATA* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 3 LBA120L Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25 °C) IF = 5mADC 35 30 25 20 15 10 5 0 1.17 1.19 1.21 1.23 1.25 LED Forward Voltage Drop (V) LBA120L - Form A Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 35 30 25 20 15 10 5 0 14.0 14.8 15.6 14.4 15.2 On-Resistance ( Ω) LBA120L - Form B Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 35 30 25 20 15 10 5 0 10.4 10.8 11.2 12.0 11.6 12.4 On-Resistance ( Ω) LBA120L - Form A Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 35 30 25 20 15 10 5 0 380 388 396 384 392 400 Blocking Voltage (V) LBA120L - Form B Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 35 30 25 20 15 10 5 0 291.25 293.75 296.25 298.75 301.25 303.75 Blocking Voltage (V) LBA120L - Form A Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC 40 35 30 25 20 15 10 5 0 0.8 1.2 1.6 0.6 1.0 1.4 1.8 LED Current (mA) ) LBA120L - Form B Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 0.63 0.81 1.17 1.53 0.99 1.35 LED Current (mA) 30 25 20 15 10 5 0 LBA120L - Form A Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 0.5 0.9 1.3 0.3 0.7 1.1 1.5 LED Current (mA) 25 20 15 10 5 0 LBA120L - Form B Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC) 35 25 20 15 10 5 0 0.63 0.99 1.35 0.45 0.81 1.17 LED Current (mA) LBA120L - Form A Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC; IF = 5mADC) 0.23 0.41 0.59 0.77 0.68 0.50 0.32 Turn-On (ms) 30 25 20 15 10 5 0 LBA120L - Form B Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC; IF = 5mADC) 0.42 0.66 0.90 0.54 0.78 Turn-On (ms) 35 30 25 20 15 10 5 0 0.30 LBA120L - Form A Typical Turn-Off Time (N=50 Ambient Temperature = 25 °C) (Load Current = 170mADC; IF = 5mADC) 0.06 0.14 0.22 0.30 0.10 0.18 0.26 Turn-Off (ms) 35 30 25 20 15 10 5 0 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |