| 数据搜索系统,热门电子元器件搜索 |
|
LBA120LS 数据表(PDF) 5 Page - Clare, Inc. |
|
|
|||||||||||||||||||||||||||||
LBA120LS 数据表(HTML) 5 Page - Clare, Inc. |
|
5 / 8 page ![]() LBA120L www.clare.com 5 Rev. 3 PERFORMANCE DATA* *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. LBA120L - Form A Typical Turn-On vs. LED Forward Current (Load Current = 170mADC) LED Forward Current (mA) 0 2 4 6 8 10 12 14 16 18 0.40 0.35 0.30 0.25 0.20 0.15 0.10 20 LBA120L - Form B Typical Turn-On vs. LED Forward Current (Load Current = 170mADC) LED Forward Current (mA) 0 5 1015202530354045 0.634 0.632 0.630 0.628 0.626 0.624 0.622 50 LBA120L - Form A Typical Turn-Off vs. LED Forward Current (Load Current = 170mADC) LED Forward Current (mA) 0 2 4 6 8 10 12 14 16 18 20 0.160 0.150 0.140 0.130 0.120 0.110 0.100 LBA120L - Form B Typical Turn-Off vs. LED Forward Current (Load Current = 170mADC) LED Forward Current (mA) 0 5 1015202530354045 1.2 1.0 .8 .6 .4 .2 0 50 LBA120L - Form A Typical On-Resistance vs. Temperature (Load Current = 170mADC; IF = 5mA) Temperature ( °C) -40 60 50 40 30 20 10 0 -20 0 20 40 60 80 100 LBA120L - Form B Typical On-Resistance vs. Temperature (Load Current = 170mADC; IF = 5mADC) Temperature ( °C) -40 60.000 50.000 40.000 30.000 20.000 10.000 0 -20 0 20 40 60 80 100 LBA120L - Form A Typical IF for Switch Operation vs. Temperature (Load Current = 170mADC) Temperature ( °C) -40 3.000 2.500 2.000 1.500 1.000 0.500 0 -20 0 20 40 60 80 100 LBA120L - Form B Typical IF for Switch Operation vs. Temperature (Load Current = 170mADC; IF = 5mADC) Temperature ( °C) -40 3.0 2.5 2.0 1.5 1.0 0.5 0 -20 0 20 40 60 80 100 LBA120L - Form A Typical IF for Switch Dropout vs. Temperature (Load Current = 170mADC) Temperature ( °C) -40 3.000 2.500 2.000 1.500 1.000 0.500 0 -20 0 20 40 60 80 100 LBA120L - Form B Typical IF for Switch Dropout vs. Temperature (Load Current = 170mADC) Temperature ( °C) -40 3.0 2.5 2.0 1.5 1.0 0.5 0 -20 0 20 40 60 80 100 LBA120L - Form A Typical Load Current vs. Load Voltage (Ambient Temperature = 25 °C) IF = 5mADC Load Voltage (V) 200 150 100 50 0 -50 -100 -150 -200 -2.5 -1.5 -2.0 -0.5 -1.0 0 0.5 1.5 2.0 1.0 2.5 LBA120L - Form B Typical Load Current vs. Load Voltage (Ambient Temperature = 25 °C) IF = 5mADC Load Voltage (V) 200 150 100 50 0 -50 -100 -150 -200 -2.0 -1.5 -1.0 -0.5 0.5 1.0 1.5 0 2.0 LBA120L Energy Rating Curve Time 10 µs 1.2 1.0 0.8 0.6 0.4 0.2 0 1ms 100 µs 100ms 1s 10ms 10s 100s LBA120L Typical Current Limiting vs. Temperature IF = 5mADC Temperature ( °C) 400 350 300 250 200 150 100 50 0 -40 -20 0 20 40 60 80 100 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |