2 / 13 page ![]() DS1682 2 of 13 The DS1682 uses a calibrated, temperature compensated RC time base to increment an elapsed time counter while an event is active. When the event becomes active, the contents of the non-volatile Total Time Accumulator register are downloaded to the Elapsed Time Counter (ETC) and as the event continues, the ETC is incremented in quarter second increments. When the event becomes inactive or the power is removed, the DS1682 will increment the 17-bit non-volatile Event Counter register and put the contents of the ETC into the 32-bit non-volatile Total Accumulated Time register which can hold up to 34 years of active event time. A storage cap may be required on VCC to provide enough power to store the value in the ETC to the Total Time Accumulator register if power is taken away at the same time the event ends. When the 32-bit non-volatile Alarm Trip Point register is programmed to a non-zero number via the 2-wire bus and the AoR bit in the Configuration register set to a zero, the Alarm# output will be enabled and the DS1682 will begin to monitor the values in the ETC for the programmed value in the Alarm Trip Point register. Once the number in the ETC is equal to or greater than the value in the Alarm Trip Point register, and the polarity bit is set to a zero, the Alarm# output will become active to alert the user, or with the polarity bit set to a one, the Alarm# output will become inactive when the values match. The DS1682 will activate the Alarm# output by pulling the pin low four times at power up, when the alarm becomes active, or when the Alarm# pin is pulled low and released if the AOS bit is set to a 1. If the AOS bit is a 0, the Alarm# output will be constantly low when the alarm is active. In order to reset the device, the Reset Enable bit or the AoR bit in the Configuration register must be set to a 1. With the Reset Enable bit set to a 1 or the AoR bit set to a 1 with the Alarm# pin held high, the DS1682 can be reset by the Reset command sent over the 2-wire bus. If the Write Disable flag in the Configuration register is set to a 1 by writing the Write Disable command two times, the Configuration registers and Alarm Trip Point register will not be able to be written. If the Write Disable flag is set to a 1, the Total Time Accumulator, Elapsed Time Counter, and Event Counter will be able to be reset, if the Reset Enable or AoR bits have been set to a 1, but the status of the Reset Enable or AoR bits will not be able to be changed since the Configuration register is locked by the WDF being set to a 1. The Write Memory Disable is similar to the Write Disable and is used to control the writability of the 10 bytes of EEPROM User memory. The Write Memory Disable Flag is also set to a 1 when the Write Memory Disable command is written twice and can not be changed once it is set to a 1. If the Write Memory Disable bit is set to a 1, the 10 bytes of memory will not be able to be written or erased. If the Write Memory Disable bit is a 0, the user will have full access to the bytes with the standard EEPROM write time restrictions. If the Write Disable is a 0, the device is fully writable or erasable except for the User Memory and the Write Memory Disable flag, which are only controlled by the Write Memory Disable command. With both the Write Disable and Write Memory Disable set to 1’s, the only inputs that will be accessible are the Reset command if it is enabled, the Event input and the Alarm# input/output. The rest of the part will be read only. When data is written to the device, the device slave address will be sent first followed by the address pointer and the desired byte of data. Once a single byte of data is sent, there must be at least 200 mS to allow the EEPROM to update the data. OVERVIEW The block diagram in Figure 1 shows the relationship between the major control and memory I/O sections of the DS1682. The device has three major components: 1) clock generator and control blocks, 2) elapsed time counter and accumulator registers, and 3) 2-wire interface. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |