| 数据搜索系统,热门电子元器件搜索 |
|
SAP51D-B-G1-R 数据表(PDF) 42 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
SAP51D-B-G1-R 数据表(HTML) 42 Page - List of Unclassifed Manufacturers |
|
42 / 63 page ![]() SAP5S / SAP51 Universal Actuator-Sensor Interface IC Data Sheet July 17, 2012 © 2012 Zentrum Mikroelektronik Dresden AG — Rev. 3.1 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to changes without notice. 42 of 62 4.12. Oscillator Pins OSC1, OSC2 Table 28: Oscillator pin parameters Symbol Parameter Min Max Unit Note VOSC_IN Input voltage range -0.3 VU5R V COSC External parasitic capacitor at oscillator pins OSC1, OSC2 0 8 pF CCRYSTAL Crystal load capacitance 0 12 pF VIL Input ”low” voltage 0 1.5 V 1 VIH Input ”high” voltage 3.5 VU5R V 1 1 for external clock applied to OSC1 The oscillator supports direct connection of 5.33 MHz or 16.000 MHz crystals with a dedicated load capacity of 12pF and parasitic pin capacities of up to 8pF. The IC automatically detects the oscillation frequency of the connected crystal and controls the internal clock generator circuit accordingly. The oscillator unit also contains a clock watch dog circuit that can generate an unconditioned IC reset if there was no clock oscillation for more than about 20µs. This is to prevent the IC from unpredicted behavior if no clock signal is available anymore. 4.13. IC Reset Any IC reset turns the Data Output and Parameter Output Registers to 0xF and forces the corresponding output drivers to high impedance state. Except at Power On Reset, Data Strobe and Parameter Strobe signals are simultaneously generated to visualize possibly changed output data to external circuitry. The Data_Exchange_Disable flag becomes set during IC reset, prohibiting any data port activity right after IC initialization and as long as the external circuitry was not pre-conditioned by decent parameter output data. Consequently the AS-i master has to send a Write_Parameter call in advance of the first Data_Exchange request to an initialized slave. Following IC initialization times apply: Table 29: IC Initialization times Symbol Parameter Min Max Unit Note tINIT Initialization time after Software Reset (generated by master calls Reset_Slave or Broadcast_Reset) or external reset via DSTBn 2 ms 1 tINIT2 Initialization time after power on 30 ms 2 tINIT3 Initialization time after power on with high capacitive load 1000 ms 3 1 guaranteed by design 2 ‘power on’ starts latest at V UIN = 18V, external capacitor at pin UOUT less than or equal 10µF 3 C UOUT = 470µF, tINIT3 is guaranteed by design only 4.13.1. Power On Reset In order to force the IC into a defined state after power up and to avoid uncontrolled switching of the digital logic if the 5V supply (U5R) breaks down below a certain minimum level, a Power On Reset is executed under the following conditions: Table 30: Power On Reset Threshold Voltages Symbol Parameter Min Max Unit Note VPOR1F VU5R voltage to trigger internal reset procedure, falling voltage 1.2 1.7 V 1 VPOR1R VU5R voltage to trigger INIT procedure, rising voltage 3.5 4.3 V 1 tLow Power-on reset pulse width 4 6 µs 1 guaranteed by design |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |