9 / 11 page ![]() AN3398 Calibration flow chart Doc ID 018812 Rev 1 9/11 R1 = R2 * (Vn - VDIV) / VDIV [Ohm] 1.1.4 Online procedure According to the used current sensor and the chosen algorithm, a component (resistor or current sensor) of the value calculated through the formulas above must be mounted on the board. To start the online calibration procedure, the following must be verified: ● EM is connected to the calibration system and is properly configured according to the chosen application ● EM calibrator parameters are preset to initial data ● Target values of line signals are stable. A 3-phase voltage signal must be provided to all phases and current signal only to the phase under calibration. When the system is connected and powered on, a certain number of readings of the RMS values must be performed. Due to the fact that 0.4% of ripple is present in the measured RMS values, more than ten readings of these values should be gathered each cycle (20 ms at 50 Hz) and the average values of RMS current and voltage readings AvI and AvV should be computed. Consequently, having the average values AvI and AvV, a pair of final 8-bit (or 10-bit if PM = 1) calibration data can be calculated as shown below: Equation 27 Ci,v = 896 * XI,V / AvI, V - 768; (PM = 0) Equation 28 Ci,v = 8192 * XI,V / AvI, V - 7168; (PM = 1) where XV and XI are those calculated in one of the four previous cases. 1.1.5 Coherency check We can assume that the EM works correctly and that built-in voltage and current sensors allow the target power sensitivity constant to be achieved, because the correction parameters Ki and Kv can tune measured values within the calibration range of ±12.5% or ±6.25% if PM =1 per voltage or current channel. If, after the calibration, calculated values for Cv or Ci are out of their 8 or 10-bit range, it may mean that the application cannot reach the target value of power sensitivity. In this case, steps 3 and 4 must be repeated choosing a smaller power sensitivity value. If the values of Cv or Ci are out of range even for small values of PM, it may mean that the energy meter board is not good enough to perform such measurements, possibly because the tolerance of the components is too big, or no care has been taken in the layout phase, so the application must be re-designed. Otherwise, if the final calibrator data is written into STPMC1, the average RMS readings are very close to target values XI and XV and the frequency of the LED output are very close to the target value f. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |