5 / 11 page ![]() AN3398 Calibration flow chart Doc ID 018812 Rev 1 5/11 Only analog parameters are objects of calibration because they introduce a certain error. Voltage ADC amplification Av is constant, while Ai is chosen according to the used sensors. The calibration procedure has, as a final result, correction parameters called KVR, KVS, KVT and KIR, KIS, KIT and KIN (if used) which, applied to STPMC1 voltage and current measurements, compensate small tolerances of analog components that affect energy calculations. As KVR, KVS, KVT and KIR, KIS, KIT and KIN calibration parameters are the decimal representation of the corresponding configuration bytes CVR, CVS, CVT and CIR, CIS, CIT, CIN, the values of those bits are obtained at the end of calibration. In the following procedure CVR, CVS, and CVT are indicated as Cv; CIR, CIS, CIT, and CIN are indicated as Ci; KVR, KVS, and KVT are indicated as Kv, and KIR, KIS, KIT, and KIN are indicated as Ki. Through hardwired formulas, Kv and Ki tune measured values varying from 0.75 to 1 in 256 steps, according to the value of Cv and Ci (from 0 to 255). If PM=1, two bits are appended to each Cv and Ci (see the STPMC1 datasheet for details), and the corresponding tunings vary from 0.875 to 1 in 1024 steps. To initially obtain the greatest correction dynamic, calibrators are set in the middle of the range, therefore obtaining a calibration range of ± 12.5% (± 6.25% when PM is set) per voltage or current channel: In this way it is possible to tune Kv and Ki having a precise measurement: for example, with PM=0, Cv=0 generates a correction factor of -12.5% (Kv=0.75) and Cv=255 determines a correction factor of +12.5% (Kv=1), and so on. According to the information above, the following formulas, which relate Kv,i and Cv,i to each other are obtained: Equation 1 Kv,i = (Cv,i/128) * 0.125 + 0.75 Equation 2 Cv,i = 1024 * Kv,i - 768 or when PM = 1 Equation 3 Kv,i = (Cv,i/512) * 0.0625 + 0.875 Equation 4 Table 3. Calibrator value according to PM PM Calibrator value 0 Kv = Ki = 0.875 Ci = Cv = 128 1 Kv = Ki = 0.9375 Ci = Cv = 512 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |