| 数据搜索系统,热门电子元器件搜索 |
|
AN2744 数据表(PDF) 31 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN2744 数据表(HTML) 31 Page - STMicroelectronics |
|
31 / 56 page ![]() AN2744 Board description 31/56 5.2 Conducted disturbances 5.2.1 Conducted emissions The EN50065-1 standard describes test setup and procedures for this kind of test. The measures have been done with 220 VAC mains voltage. The test pattern consists of a continuous transmission of a fixed tone at a frequency of 70.8 kHz (72 kHz center frequency minus half the FSK frequency deviation, in this case 2400 Hz) which corresponds to a symbol "1". The output signal measured at the artificial network has a value of 120 dBµV rms, which means a 2 V rms signal on the mains output of the board. The spectrum analyzer performs a peak measure instead of a quasi-peak measure. For continuous sinusoidal signals, the two types of measurement give the same result. Figure 25. Measured input impedance magnitude of the coupling interface in Tx mode for the 86 kHz channel (typical curve) 1 10 100 1000 1E+04 1E+05 1E+06 Freq (Hz) EN50065 EN50065--7 7 1 10 100 1000 1E+04 1E+05 1E+06 Freq (Hz) EN50065 EN50065--7 7 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|