39 / 56 page ![]() AN2744 Board description 39/56 5.5 Surge and burst protection The specific structure of the coupling interface circuit of the application is a weak point against high voltage disturbances that can come from the external environment. In fact an efficient coupling circuit with low insertion losses realizes consequently a very low impedance path from the mains to the power line interface of the device. For this reason it's recommended to add some specific protections on the mains coupling path, in order to prevent high energy disturbances coming from the mains from damaging the internal power circuitry of the ST7538Q. The possible environments for this kind of application can be both indoor and outdoor: residential, commercial and light-industrial locations. To verify the immunity of the system to environmental electrical phenomena, a series of immunity specification standards and tests must be applied to the power line application. The requirements for ac-connected ports include EN610000-4-4 (electric fast transients), EN610000-4-5 (surges), EN610000-4-6 (RF out-of-band disturbances), EN610000-4-11 (voltage dips). All these tests are listed in the EN50065-2-3 document (part 7, immunity specifications). In particular, surge tests are specified as both common and differential mode at level +/- 4 kV, with pulse shape 1.2 x 50 µs. Fast transient burst tests are specified at level +/- 2 kV, with pulse shape 5 x 50 ns and pulse frequency 5 kHz. Figure 37 and Figure 38 illustrate the protection criteria implemented in the ST7538Q reference design. Figure 37 shows the protection against common mode disturbances. The ESD Transil™ protection diodes are able to absorb quickly fast transient disturbances starting from their 6.1 V threshold voltage. Figure 38 describes the protection intervention in case of differential mode disturbances. A differential voltage higher than 6.8 V is shorted by the bidirectional power Transil™, which is the most robust protection and also the one that is able to absorb most of the energy of any incoming disturbance. Figure 37. Common mode disturbances protection ATOP1 ATOP2 N P 3 1 2 1 8 4 5 ATOP1 ATOP2 N P 3 1 2 1 8 4 5 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |