| 数据搜索系统,热门电子元器件搜索 |
|
AN3213 数据表(PDF) 39 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3213 数据表(HTML) 39 Page - STMicroelectronics |
|
39 / 64 page ![]() AN3213 ST7570 demonstration board description Doc ID 17429 Rev 1 39/64 Noise and signal are measured independently on the RX_IN pin of the ST7570 through a spectrum analyzer with a differential 1 M Ω probe. When measuring the signal level S S (expressed in dBµV rms), the transmitting ST7570 device is set in continuous transmission of a single sine tone, allowing the measurement of the signal level to be performed with a resolution bandwidth (RBW) of 100 Hz. The probe was removed during communication tests to avoid any interference. 7.2.3 AWGN tests These tests are aimed at testing the demonstration board performance against AWGN and guaranteeing compliance with IEC61334-5-1 requirements (References 5). The value of injected noise has been kept constant during all performance tests; different SNR values have been set by changing the signal level on the transmitting ST7570 device. The measured noise level has been obtained with an RBW equal to 3 kHz. As the spectrum analyzer is integrating the noise spectral density over its RBW, the actual noise level SN (expressed in dBµV rms) can be obtained by scaling the measured value to the modulated signal bandwidth SBW (that is, 1200 or 2400 Hz according to the baud rate). Equation 10 expresses the relationship between measured and actual noise level. Equation 10 Table 6 gives the actual noise level at each S-FSK tone frequency in the test setup of Figure 33. The signal-to-noise ratio (SNR) values for the two S-FSK tones can be calculated as: and . The average SNRAV is calculated in accordance with Equation 11 as in References 3: Equation 11 The difference found between noise levels on f0 and f1 frequencies is mostly due to non-flat response of transmission and reception filters. Nevertheless, these values can be considered as a real case for evaluating the ST7570 demonstration board performance in communication tests. SS0 and SS1 have the same unbalancing, so the resulting difference between SNR0 and SNR1 is about 1 dB. Table 6. Noise level SN0 and SN1 during AWGN tests SBW [Hz] SN0 [dBμV rms] SN1 [dBμV rms] 1200 41.12 39.82 2400 44.13 42.83 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |