数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

AN441 数据表(PDF) 9 Page - STMicroelectronics

部件名 AN441
功能描述  Inductive load control with AC switches
PDF  16 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  STMICROELECTRONICS [STMicroelectronics]
网页  http://www.st.com
标志 STMICROELECTRONICS - STMicroelectronics

AN441 数据表(HTML) 9 Page - STMicroelectronics

Back Button AN441 Datasheet HTML 5Page - STMicroelectronics AN441 Datasheet HTML 6Page - STMicroelectronics AN441 Datasheet HTML 7Page - STMicroelectronics AN441 Datasheet HTML 8Page - STMicroelectronics AN441 Datasheet HTML 9Page - STMicroelectronics AN441 Datasheet HTML 10Page - STMicroelectronics AN441 Datasheet HTML 11Page - STMicroelectronics AN441 Datasheet HTML 12Page - STMicroelectronics AN441 Datasheet HTML 13Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 16 page
background image
AN441
Typical examples of inrush current reduction
Doc ID 3579 Rev 3
9/16
Triac turn on at peak mains voltage allows the reduction of the peak inrush current by 75%
compared to a zero voltage switch on as shown in Figure 8.
The reduction of first peak current allows:
Use of a lower Triac range (lower IT(RMS) range),
Safer margin for the Triac (ITSM).
3.2
Transformer for lighting
A Triac could be used to dim SELV (safety extra low voltage) halogen lamps. In this case the
lamps are connected at the secondary winding of a 220 V to 12 V step-down transformer.
The Triac is then connected on this transformer in series with the primary winding (Figure 9).
The power applied to the lamp is controlled by the variation of the conducting angle of the
Triac and allows dimming the brightness of the lamp.
Figure 9.
Typical schematic of a light dimmer for SELV halogen lamps
Like microwave oven transformers, transformers for lighting application present an
overcurrent if they are switched on at zero voltage due to magnetizing current.
This inrush current is increased if the lamp filament is cold. Filament resistance decreases
when the temperature decreases.
The high current due to the cold filament effect could cause transformer magnetic core
saturation, which then drastically increases the primary winding inrush current.
To reduce the inrush current, an appropriate triggering needs to be used. Table 1 shows
different halogen lamp test results used with a transformer. The table shows that the
maximum peak current is lower when the load is triggered at zero current.
Indeed the ratio between peak current at zero voltage and at peak voltage triggering is in the
range of 2 to 4. It should also be noted that, in case of triggering at peak voltage, some
transformers (transformer 1 and 2) have a peak inrush current close to 13 times the steady
state peak current whereas others feature a ratio lower than 7 (transformer 3). This is linked
to the low-saturation level of some low-quality transformers.
V
MAINS



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com