5 / 16 page ![]() AN1798 STR71x ADC features 5/16 2.2 ADC output, Gain and offset features The converted values stored in ADC_DATA[n] 16-bit register are signed two’s complement values and only the 12 most significant bits are used. The following figure gives the ADC output versus the input voltage. Figure 3. ADC output ADC_DATA(0V) and ADC_DATA(2.5V) are the conversion of 0V and 2.5V respectively. The gain of the ADC is given by: G = [0xFFF - ADC_DATA(0V) + ADC_DATA(2.5V)] / 2.5 The quantum is calculated by the following equation: q = 2.5V / [0xFFF - ADC_DATA(0V) + ADC_DATA(2.5V)] The offset is the digital unsigned value of 0V (ADC_DATA(0V)) and the application should subtract this offset when reading all the conversion results. 2.3 Round-Robin and Single channel modes These modes are provided to simplify the use of the ADC. ● Single channel mode selects one channel that is the only channel input to the Sigma- Delta modulator. To use single channel mode, bit 6 in the ADC_CSR register must be set to 1. A valid sample in this mode is produced every 2048 modulator clock cycles. ● Round-Robin mode (which is the normal mode) allows you to simplify your software code and avoid using an endless loop (while (1)) to get the converted values of all channels continuously. This process is repeated for each of the channels continually in a round-robin fashion. A valid sample in this mode is produced every 512 modulator clock cycles for each channel. 2.4 Conversion data availability and interrupt generation The End of Conversion is indicated by four flags or by interrupt generation. The four flags are the Data Available flags (DA[n]) in the Control Status register. They allow the application software to determine which channel data register has a new sample ready to be read. Each DA[n] flag corresponds to ADC channel n. They are set by hardware as soon as a new sample on the corresponding channel is available and they are automatically cleared when the corresponding data register is read. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |