6 / 24 page ![]() Temperature sensor overview AN3397 6/24 Doc ID 018809 Rev 1 1.3 Temperature sensor accuracy Without calibration the TS is likely to give error readings in the order of ±30 °C. If the sensor is calibrated, significantly more accurate temperature measurements can be obtained. For example, if the TS characteristic slope and offset are calibrated, a five-fold improvement in accuracy over the full temperature range can be obtained. Even greater accuracy is possible if the temperature range is limited (see Figure 1). STM8L15xxx devices are provided with a calibration data point, V90, which is factory measured at hot temperatures (90 °C ± 5 °C) during the manufacturing process and stored in the protected memory area of the device at address 0x4911 (see device datasheet for details). This single calibration point may be sufficient depending on the precision required by the application, but it is highly recommended to perform a second calibration point (user calibration point) at ambient temperature. Devices with a two-point calibration are generally suitable for most embedded applications because the deviation versus the ideal linear curve is restrained and the individual characteristics of the temperature sensor are respected. 1.4 Temperature sensor engineering tolerance The engineering tolerance of the temperature estimation is illustrated in Figure 1. It is limited by two boundary lines: the minimum biased values (green line) and the maximum biased values (blue line). This tolerance is directly linked to both the temperature margin of the factory calibrated data at hot temperatures (V90 = 90 °C ± 5 °C) and the Avg_slope uncertainty (1.62 mV/°C ± 0.03 mV/°C) specified in the STM8L15xxx datasheets. Figure 1 shows that the user calibration point significantly improves the accuracy of the temperature measurement since reducing the whole temperature tolerance area to a lower range means that more reasonable results are obtained. The recommended position of the calibration points should be as close as possible to the minimum and maximum values of the measurement range to cover the full device temperature range. However, the user calibration point can be performed at ambient temperature (20 °C to 25 °C) as it is the easiest way to proceed. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |