21 / 24 page ![]() AN3397 Software description Doc ID 018809 Rev 1 21/24 Figure 7. Infinite routine flowchart While(1) Advanced mode ? Forced calibration flag set ? Display ‘CAL ...’ on LCD screen Execute the calibration routine user_calib() Wakeup flag set ? Temperature = average of last 20 temperature measurements D Yes Yes Yes Yes No No C C No No Temperature measurement performed by ADC Number of samples > 20 ai18765 5-minute counter expired ? Is temperature > temperature measured 5 mins before ? B BAR 3 displayed on the LCD screen No bar displayed on the LCD Is temperature > maximum temperature recorded so far ? Maximum temp = current temp User push-button used to disply max, min, and current temperature D Yes Yes Yes C No No No No Yes No Is temperature < temperature measured 5 mins before ? BAR 0 displayed on the LCD screen Is temperature < minimum temperature recorded so far ? Minimum temp = current temp |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|