| 数据搜索系统,热门电子元器件搜索 |
|
TC850CPL 数据表(PDF) 12 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
TC850CPL 数据表(HTML) 12 Page - Microchip Technology |
|
12 / 26 page ![]() TC850 DS21479C-page 12 © 2006 Microchip Technology Inc. 6.0 DIGITAL SECTION DESCRIPTION The TC850 digital section consists of two sets of con- version counters, control and sequencing logic, clock oscillator and divider, data latches and an 8-bit, 3-state interface bus. A simplified schematic of the bus interface logic is shown in Figure 6-1 6.1 Clock Oscillator The TC850 includes a crystal oscillator on-chip. All that is required is to connect a crystal across OSC1 and OSC2 pins and to add two inexpensive capacitors (Figure 1-1). The oscillator output is ÷ 4 prior to clock- ing the A/D internal counters. For example, a 100 kHz crystal produces a system clock frequency of 25 kHz. Since each conversion requires 1280 clock periods, in this case the conversion rate will be 25,000/1280, or 19.5 conversions per second. In most applications, however, an external clock is divided down from the microprocessor clock. In this case, the OSC1 pin is used as the external oscillator input and OSC2 is left unconnected. The external clock driver should swing from digital ground to VDD. The ÷ 4 function is active for both external clock and crystal oscillator operations. FIGURE 6-1: Bus Interface Simplified Schematic 6.2 Digital Operating Modes Two modes of operation are available with the TC850, continuous conversions and on-demand. The Operat- ing mode is controlled by the CONT/DEMAND input. The bus interface method is different for Continuous and Demand modes of operation. 6.2.1 DEMAND MODE OPERATION When CONT/DEMAND is low, the TC850 performs one conversion each time the chip is selected and the WR input is pulsed low. Data is valid on the falling edge of the BUSY output and can be accessed using the interface truth table (Table 6-1). 6.2.2 CONTINUOUS MODE OPERATION When CONT/DEMAND is high, the TC850 continu- ously performs conversions. Data will be valid on the falling edge of the BUSY output and remains valid for 443-1/2 clock cycles. The low/high (L/H) byte-select and overrange/polarity (OVR/POL) inputs are disabled during Continuous mode operation. Data must be read in three consecutive bytes, as shown in Table 6-1. RD L/H 3-State Buffer Output Enable End of Conversion CONT/ DEMAND Start Conversion To A/D Control Logic Octal 2-Input Mux Select Low-Byte Up/Down Counter High-Byte Up/Down Counter Polarity Overrange TC850 8 Select 2-Input Mux DBO–DB7 8 7 8 CE CS WR POL/OVR Note: In Continuous mode, the conversion result must be read within 443-1/2 clock cycles of the BUSY output falling edge. After this time (i.e.,1/2 clock cycle before BUSY goes high) the internal counters are reset and the data is lost. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |