12 / 20 page ![]() ML2280, ML2283 12 ANALOG INPUTS AND SAMPLE/HOLD An important feature of the ML2280 and ML2283 is that they can be located at the source of the analog signal and then communicate with a controlling µP with just a few wires. This avoids bussing the analog inputs long distances and thus reduces noise pickup on these analog lines. However, in some cases, the analog inputs have a large common mode voltage or even some noise present along with the valid analog signal. The differential input of these converters reduces the effects of common mode input noise. Thus, if a common mode voltage is present on both “+” and “–” inputs, such as 60Hz, the converter will reject this common mode voltage since it only converts the difference between “+” and “–” inputs. The ML2280 and ML2283 have a true sample and hold circuit which samples both “+” and “–” inputs simultaneously. This simultaneous sampling with a true S/H will give common mode rejection and AC linearity performance that is superior to devices where the two input terminals are not sampled at the same instant and where true sample and hold capability does not exist. Thus, these A/D converters can reject AC common mode signals from DC-50kHz as well as maintain linearity for signals from DC- 50kHz. The signal at the analog input is sampled during the interval when the sampling switch is closed prior to conversion start. The sampling window (S/H acquisition time) is 1/2 CLK period wide and occurs 1/2 CLK period before DO goes from high impedance to active low state. When the sampling switch closes at the start of the S/H acquisition time, 8pF of capacitance is thrown onto the analog input. 1/ 2 CLK period later, the sampling switch is opened and the signal present at the analog input is stored. Any error on the analog input at the end of the S/H acquisition time will cause additional conversion error. Care should be taken to allow adequate charging or settling time from the source. If more charging or settling time is needed to reduce these analog input errors, a longer CLK period can be used. For latchup immunity each analog input has dual diodes to the supply rails, and a minimum of ±25mA (±100mA typically) can be injected into each analog input without causing latchup. ZERO ERROR ADJUSTMENT The zero of the A/D does not require adjustment. If the minimum analog input voltage value, VIN MIN is not ground, a zero offset can be done. The converter can be made to output 00000000 digital code for this minimum input voltage by biasing any VIN– input at this VIN MIN value. This utilizes the differential mode operation of the A/D. The zero error of the A/D converter relates to the location of the first riser of the transfer function and can be measured by grounding the VIN– input and applying a small magnitude positive voltage to the VIN+ input. Zero error is the difference between the actual DC input voltage which is necessary to just cause an output digital code transition from 00000000 to 00000001 and the ideal 1/2 LSB value (1/2 LSB = 9.8mV for VREF = 5.000VDC). FULL-SCALE ADJUSTMENT The full-scale adjustment can be made by applying a differential input voltage which is 1-1/2 LSB down from the desired analog full-scale voltage range and then adjusting the magnitude of the VREF input or VCC for a digital output code which is just changing from 11111110 to 11111111. ADJUSTMENT FOR AN ARBITRARY ANALOG INPUT VOLTAGE RANGE If the analog zero voltage of the A/D is shifted away from ground (for example, to accommodate an analog input signal which does not go to ground), this new zero reference should be properly adjusted first. A VIN+ voltage which equals this desired zero reference plus 1/2 LSB (where the LSB is calculated for the desired analog span, 1 LSB = analog span/256) is applied to selected “+” input and the zero reference voltage at the corresponding “–” input should then be adjusted to just obtain the 00000000 to 00000001 code transition. The full-scale adjustment should be made by forcing a voltage to the VIN+ input which is given be: V fs adjust V VV IN MAX MAX MIN += − × − 15 256 . () where VMAX = high end of the analog input range VMIN = low end (offset zero) of the analog range The VREF or VCC voltage is then adjusted to provide a code change from 11111110 to 11111111. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |