39 / 64 page ![]() E5EZ-PRR 39 Specifications Ratings Communications Specifications Power supply voltage 100 to 240 VAC, 50/60 Hz Operating voltage range 85% to 110% of rated supply voltage Power consumption 10 VA (10 W) Sensor input Temperature input type Thermocouple: K, J, T, E, L, U, N, R, S, B Platinum resistance thermometer: Pt100, JPt100 Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C Voltage input: 0 to 50 mV Analog (current, voltage) input type Current input: 4 to 20 mA, 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V Control output Relay output (OUT1,OUT2) SPST-NO, 250 VAC 1A (resistive load) Electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA Potentiometer input 100 Ω to 2.5 KΩ Alarm output SPST-NO, 250 VAC 2 A (resistive load) Electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA. Event input Contact input ON: 1 k Ω max., OFF: 100 kΩ min. Non-contact input ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. Outflow current: Approx. 7 mA per point Control method 2-PID control Setting method Digital setting using front panel keys Indication method 7-segment digital display and single-lighting indicators Character height: PV: 9 mm; SV: 7 mm; MV: 6.8 mm Other functions According to controller model Ambient operating temperature −10 to 55°C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature −25 to 65°C (with no icing or condensation) Transmission line connection RS-485: Multidrop RS-232C:Point-to-point Communications method (See note 1.) RS-485 (two-wire, half duplex)/RS-232C Synchronization method Start-stop synchronization Baud rate 1,200/2,400/4,800/9,600/19,200 bps Communications code ASCII Data length (See note 2.) 7 or 8 bits Stop bits (See note 2.) 1 or 2 bits Error detection Vertical parity (none, even, odd) Block check character (BCC) Flow control Not available Interface RS-485/RS-232C Retry function Not available |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |