| 数据搜索系统,热门电子元器件搜索 |
|
E5CZ-R2MLD 数据表(PDF) 20 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CZ-R2MLD 数据表(HTML) 20 Page - Omron Electronics LLC |
|
20 / 64 page ![]() E5AZ/E5EZ 20 Characteristics Note: 1. The indication accuracy of K thermocouples in the −200 to 1300 °C range, T and N thermocouples at a temperature of −100°C max., and U and L thermocouples at any temperature is ±2°C ±1 digit maximum. The indication accuracy of the B thermocouple at a temperature of 400 °C max. is not specified. The indication accuracy of the R and S thermocouples at a temperature of 200 °C max. is ±3°C ±1 digit max. 2. Conditions: Ambient temperature: −10°C to 23°C to 55°C, Voltage range: −15% to +10% of rated voltage 3. “EU” stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is °C or °F. 4. B, R, and S sensors: 0.2 °C/Ω max. (100 Ω max.) 5. When using the E53-AZB, E53-AZ01, or E53-AZ03 Option Unit with the E5AZ- @3@M@@ to satisfy the immunity burst requirements in the EN 61326 standard, always connect a ZCAT2035-0930 Clamp Filter (manufactured by TDK) to the cable for terminals 11, 12, and 13. USB-Serial Conversion Cable Note: A driver must be installed in the personal computer. Refer to installation information in the operation manual for the Conversion Cable. Communications Specifications Note: The baud rate, data length, stop bits, and vertical parity can be individually set using the Communications Setting Level. Current Transformer (Order Separately) Ratings Indication accuracy Thermocouple: (See note 1.) ( ±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: ( ±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. Analog input: ±0.5% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Influence of tempera- ture (See note 2.) R, S, and B thermocouple inputs: ( ±1% of PV or ±10°C, whichever is greater) ±1 digit max. Other thermocouple inputs: ( ±1% of PV or ±4°C, whichever is greater) ±1 digit max. * ±10°C for −100°C or less for K sensors Platinum resistance thermometer inputs: ( ±1% of PV or ±2°C, whichever is greater) ±1 digit max. Analog inputs: ( ±1% of FS) ±1 digit max. Influence of voltage (See note 2.) Hysteresis Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) (See note 3.) Models with analog input: 0.01 to 99.99% FS (in units of 0.01% FS) Proportional band (P) Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) (See note 3.) Models with analog input: 0.1 to 999.9% FS (in units of 0.1% FS) Integral time (I) 0 to 3999 s (in units of 1 s) Derivative time (D) 0 to 3999 s (in units of 1 s) Control period 0.5, 1 to 99 s (in units of 1 s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Alarm setting range −1999 to 9999 (decimal point position depends on input type) Sampling period 250 ms Affect of signal source resistance Thermocouple: 0.1 °C/Ω max. (100 Ω max.) (See note 4.) Platinum resistance thermometer: 0.4 °C/Ω max. (10 Ω max.) Insulation resistance 20 M Ω min. (at 500 VDC) Dielectric strength 2,000 VAC, 50 or 60 Hz for 1 min (between terminals with different charge) Vibration resis- tance Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions Shock resis- tance Malfunction 100 m/s2 min., 3 times each in X, Y, and Z directions Destruction 300 m/s2 min., 3 times each in X, Y, and Z directions Weight E5AZ Controller: Approx. 300 g, Mounting Bracket: Approx. 100 g E5EZ Controller: Approx. 250 g, Mounting Bracket: Approx. 100 g Degree of protection Front panel: IP66 (indoor use), Rear case: IP20, Terminals: IP00 Memory protection Non-volatile memory (number of writes: 1,000,000 times) EMC Emission Enclosure: EN55011 Group1 Class A Emission AC Mains: EN55011 Group1 Class A Immunity ESD: EN61000-4-2 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3) 10 V/m (900 MHz pulse modulated) Immunity Conducted Disturbance: EN61000-4-6 3 V (0.15 to 80 MHz) (level 2) Immunity Burst: EN61000-4-4 2 kV Power-line (level 3) 1 kV I/O signal-line (level 3) (See note 5.) Immunity Surge: EN61000-4-5 1kV line to line Power line, output line (relay output) 2 kV line to ground Power line, output line (relay output) 1 kV line to ground Input line (communication) Immunity Voltage Dip/Interrupting: EN61000-4-11 0.5 cycle, 100% (rated voltage) Approved standards UL 61010C-1 CSA C22.2 No.1010.1 Conformed standards EN61326, EN61010-1, IEC61010-1 VDE0106 Part 100 (Finger protection), when the terminal cover is mounted. Applicable OS Windows 2000/XP/Vista Applicable software Thermo Mini Applicable models E5CZ/E5CZ-U/E5AZ/E5EZ USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Connector specifications Computer: USB (type A plug) Temperature Controller: Setup Tool port (on bottom of Controller) Power supply Bus power (Supplied from USB host controller.) Power supply voltage 5 VDC Current consumption 70 mA Ambient operating temperature 0 to 55°C (with no condensation or icing) Ambient operating humidity 10% to 80% Storage temperature −20 to 60°C (with no condensation or icing) Storage humidity 10% to 80% Altitude 2,000 m max. Weight Approx. 100 g Transmission line con- nection method RS-485 multipoint RS-232C Communications RS-485 (two-wire, half duplex), RS-232C Synchronization method Start-stop synchronization Baud rate 1200, 2400, 4800, 9600, 19200, or 38400 bps Transmission code ASCII Data length (See note.) 7 or 8 bits Stop bits (See note.) 1 or 2 bits Error detection Vertical parity (none, even, odd) Frame check sequence (FCS) with SYSWAY Block check character (BCC) with CompoWay/F or CRC-16 Modbus Flow control None Interface RS-485, RS-232C Retry function None Communications buffer 40 bytes Send data wait time 0 to 99 ms Default: 20 ms Dielectric strength 1,000 VAC for 1 min Vibration resistance 50 Hz, 98 m/s2 Weight E54-CT1: Approx. 11.5 g, E54-CT3: Approx. 50 g Accessories (E54-CT3 only) Armatures (2) Plugs (2) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |