18 / 56 page ![]() 18 H7CX-A @-N Counter Explanation of Functions Items marked with stars ★ can be set using the DIP switch. Input Mode ( cntm)★ Set increment mode (UP), decrement mode (DOWN), or one of the increment/decrement modes (UP/DOWN A, UP/DOWN B, or UP/ DOWN C) as the input mode. Input modes other than UP or DOWN modes cannot be set using the DIP switch and so use the operation keys if other modes are required. (For details on the operation of the input modes, refer to Input Modes and Present Value on page page 21.) Dual Count Calculating Mode ( calm) When using as a dual counter, select either ADD (addition) or SUB (subtraction) as the calculation method for the dual count value. ADD: Dual count value = CP1 PV + CP2 PV SUB: Dual count value = CP1 PV − CP2 PV Output Mode ( outm)★ Set the way that control output for the present value is output. The possible settings are N, F, C, R, K-1, P, Q, A, K-2, D, L, and H. Output modes other than N, F, C, or K-1 cannot be set using the DIP switch and so use the operation keys if other modes are required. The output modes that can be set vary with the model. (For details on the operation of the output modes, refer to Input/ Output Mode Settings on page page 22.) One-shot Output Time ( otim)★ Set the one-shot output time (0.01 to 99.99 s) for control output. One-shot output can be used only when C, R, K-1, P, Q, A, or K-2 is selected as the output mode. Output times other than 0.5 s or 0.05 s cannot be set with the DIP switch and so use the operation keys if other settings are required. One-shot Output 2 Time ( otm2)★ Set the one-shot output time (0.01 to 99.99 s) for control output (OUT2). One-shot output can be used only when C, R, K-1, P, Q, A, or K-2 is selected as the output mode. Output times other than 0.5 s or 0.05 s cannot be set with the DIP switch and so use the operation keys if other settings are required. One-shot Output 1 Time ( otm1) Set the one-shot output time (0.01 to 99.99 s) for control output (OUT1). One-shot output can be used only when D, L, or H is selected as the output mode. If the output time is set to 0.00, hold is displayed, and outputs are held. Counting Speed ( cnts)★ Set the maximum counting speed (30 Hz/5 kHz) for CP1 and CP2 inputs together. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for this setting. Reset Input Signal Width ( iflt)★ Set the reset input signal width (20 ms/1 ms) for reset/reset 1 and total reset/reset 2 inputs together. If contacts are used for the input signal, set the input signal width to 20 ms. Processing to eliminate chattering is performed for this setting. Decimal Point Position ( dp) Decide the decimal point position for the present value, CP1/CP2 present values, set value (SV1, SV2), total count value, and dual count set value. Prescale Value ( pscl) Pulses input to the counter are converted according to the specified prescale value. (Setting range: 0.001 to 99.999 for 6-digit models and 0.001 to 9.999 for 4-digit models.) Example: To display the feed distance for systems that output 25 pulses for a feed length of 0.5 m in the form @@.@@ m: 1. Set the decimal point position to 2 decimal places. 2. Set the prescale value to 0.02 (0.5 ÷ 25). • Observe the following points when setting a prescale value. Set the set value to a value less than {Maximum countable value − Prescale value}. Example: If the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 − 1.25). If the set value is set to a value greater than this, output will not turn ON. • Output will turn ON, however, if a present value overflow occurs (FFFFFF or FFFF). NPN/PNP Input Mode ( imod) Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. When using a two-wire sensor, select NPN input. The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page page 9. Display Color ( colr) (Displayed for terminal block models (except H7CX-A11 @) only.) Set the color used for the present value. * Output 2 for 2-stage models. With the twin counter, output 1 and output 2 will both turn OFF when the output status is OFF. Either output 1 or output 2 will turn ON when the output status is ON. Output OFF* Output ON* red Red (fixed) grn Green (fixed) org Orange (fixed) r-g Red Green g-r Green Red r-o Red Orange o-r Orange Red g-o Green Orange o-g Orange Green 25 pulses Encoder 0.5 m Note: If the prescale value setting is incorrect, a counting error will occur. Check that the settings are correct before using this function. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |