| 数据搜索系统,热门电子元器件搜索 |
|
H7CX-R11-N 数据表(PDF) 52 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CX-R11-N 数据表(HTML) 52 Page - Omron Electronics LLC |
|
52 / 56 page ![]() H7CX- @-N 52 Safety Precautions for All H7CX Series (Common) Do not allow pieces of metal, wire clippings, or fine metallic shavings or fillings from installation to enter the product. Doing so may occasionally result in electric shock, fire, or malfunction. Minor injury due to explosion may occasionally occur. Do not use the Counter where subject to flammable or explosive gas. Fire may occasionally occur. Tighten the terminal screws to the rated torque. H7CX terminals: 6.55 to 7.97 lb-in (0.74 to 0.90 N·m) P2CF Socket terminals: 4.4 lb-in (0.5 N·m) Minor injury due to electric shock may occasionally occur. Do not touch any of the terminals while power is being supplied. Be sure to mount the terminal cover after wiring. The life expectancy of the output relay varies considerably according to its usage. Use the output relay within its rated load and electrical life expectancy. If the output relay is used beyond its life expectancy, its contacts may become fused or there may be a risk of fire. Also, be sure that the load current does not exceed the rated load current and when using a heater, be sure to use a thermal switch in the load circuit. Minor electric shock, fire, or malfunction may occasionally occur. Do not disassemble, modify, or repair the Counter or touch internal components. • The panel surface of the H7CX-A/-R is water-resistant (conforming to NEMA4, IP66, UL Type 4X (Indoor Use Only). To protect the internal circuits from water penetration through the space between the H7CX and operating panel, waterproof packing is included. Attach the Y92F-30 Adapter with sufficient pressure with the reinforcing screws so that water does not penetrate the panel. • When mounting the Counter to a panel, tighten the two mounting screws alternately, a little at a time, so as to keep them at an equal tightness. If the panel screws are tightened unequally, water may enter the panel. • Store the Counter at the specified temperature. If the Counter has been stored at a temperature of less than −10°C, allow the Counter to stand at room temperature for at least 3 hours before use. • Mounting the Counter side-by-side may reduce the life expectancies of internal components. • Use the Counter within the specified ranges for the ambient operating temperature and humidity. • Do not use in the following locations: • Locations subject to sudden or extreme changes in temperature. • Locations where high humidity may result in condensation. • Do not use the Counter outside of the rated ranges for vibration, shock, water exposure, and oil exposure. • Do not use this Counter in dusty environments, in locations where corrosive gasses are present, or in locations subject to direct sunlight. • Install the Counter well away from any sources of static electricity, such as pipes transporting molding materials, powders, or liquids. • Internal elements may be destroyed if a voltage outside the rated voltage range is applied. • Be sure that polarity is correct when wiring the terminals. • Separate the Counter from sources of noise, such as devices with input signals from power lines carrying noise, and wiring for I/O signals. • Do not connect more than two crimp terminals to the same terminal. • Up to two wires of the same size and type can be inserted into a single terminals. • Use the specified wires for wiring. Applicable Wires: AWG 18 to AWG 22, solid or twisted, copper • Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. • When the Counter is operated with no-voltage input (NPN input), approximately 14 V is output from the input terminals. Use a sensor that contains a diode. • Use a switch, relay, or other contact so that the rated power supply voltage will be reached within 0.1 seconds. If the power supply voltage is not reached quickly enough, the Counter may malfunction or outputs may be unstable. • Use a switch, relay, or other contact to turn the power supply OFF instantaneously. Outputs may malfunction and memory errors may occur if the power supply voltage is decreased gradually. • When changing the set value during operation, because the H7CX uses a constant read-in system, output will turn ON if the set value is equal to the present value. • When changing the comparison value during operation, because the H7CX uses a constant read-in system, the output status will change if the comparison value is changed to a value on the other side of the present value. • If the set value and present value are both 0, the output will turn ON for the default setting. The output will turn OFF during a reset operation. • When the power is turned ON using the factory settings, the output will turn ON after 999.9 s if no pulses are received as count input. • Do not use organic solvents (such as paint thinners or benzine), strong alkali, or strong acids. They will damage the external finish. • Confirm that indications are working normally, including the backlight LED, and LCD. The indicator LEDs, LCD, and resin parts may deteriorate more quickly depending on the application environment, preventing normal indications. Periodic inspection and replacement are required. • The waterproof packing may deteriorate, shrink, or harden depending on the application environment. Periodic inspection and replacement are required. CAUTION Precautions for Safe Use 0.5 to 1 mm It is recommended that the space between the screw head and the Adapter be 0.5 to 1 mm. Input 0 V Sensor Diode |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |