| 数据搜索系统,热门电子元器件搜索 |
|
USB2533 数据表(PDF) 29 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
USB2533 数据表(HTML) 29 Page - Microchip Technology |
|
29 / 50 page ![]() USB 2.0 Hi-Speed 3-Port Hub Controller Datasheet 2014 Microchip Technology Inc. DS00001702A-page 29 "Pin Descriptions," on page 10 and are identified by an underlined symbol name. The following sub- sections detail the various configuration straps. Configuration straps include internal resistors in order to prevent the signal from floating when unconnected. If a particular configuration strap is connected to a load, an external pull-up or pull-down should be used to augment the internal resistor to ensure that it reaches the required voltage level prior to latching. The internal resistor can also be overridden by the addition of an external resistor. Note: The system designer must guarantee that configuration straps meet the timing requirements specified in Section 9.5.2, "Reset and Configuration Strap Timing," on page 45 and Section 9.5.1, "Power-On Configuration Strap Valid Timing," on page 44. If configuration straps are not at the correct voltage level prior to being latched, the device may capture incorrect strap values. Note: Configuration straps must never be driven as inputs. If required, configuration straps can be augmented, or overridden with external resistors. 6.3.1 Non-Removable Device (NON_REM[1:0]) The NON_REM[1:0] configuration straps are sampled at RESET_N negation to determine if ports [3:1] contain permanently attached (non-removable) devices as follows. Additionally, because the SUSP_IND indicator functionality is shared with the NON_REM0 configuration strap, the active state of the LED connected to SUSP_IND will be determined as follows: Note: If using the local power detect function (LOCAL_PWR pin), the NON_REM[1:0] configuration straps cannot be used to configure the non-removable state of the USB ports. In this case, the non-removable state of the ports must be configured in internal device registers via the Protouch tool or SMBus. 6.3.2 Configuration Select (CFG_SEL[1:0]) Refer to Section 6.1, "Configuration Method Selection," on page 26 for details on CFG_SEL[1:0]. 6.3.3 Downstream Battery Charging Enable (BC_EN[3:1]) The battery charging enable configuration straps are used to enable battery charging on the corresponding downstream port. For example, if BC_EN1 is driven high during the configuration strap latching time, downstream port 1 will indicate support of battery charging. Refer to Section 8.1.2, "Downstream Battery Charging," on page 34 for additional information on battery charging. Table 6.2 NON_REM[1:0] Configuration Definitions NON_REM[1:0] DEFINITION ‘00’ All USB ports removable, SUSP_IND LED active high ‘01’ Port 1 is non-removable, SUSP_IND LED active low ‘10’ Ports 1 & 2 are non-removable, SUSP_IND LED active high ‘11’ Ports 1, 2 & 3 are non-removable, SUSP_IND LED active low |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |