| 数据搜索系统,热门电子元器件搜索 |
|
DRV10983ZPWPR 数据表(PDF) 13 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
DRV10983ZPWPR 数据表(HTML) 13 Page - Texas Instruments |
|
13 / 58 page ![]() VCC SWGND IC SW VREG 3.3 V/5 V Load 47 µH 10 µF VCC SWGND IC SW VREG 3.3 V/5 V 39 10 µF 13 DRV10983 www.ti.com SLVSCP6C – JULY 2014 – REVISED MAY 2016 Product Folder Links: DRV10983 Submit Documentation Feedback Copyright © 2014–2016, Texas Instruments Incorporated 9.3 Feature Description 9.3.1 Regulators 9.3.1.1 Step-Down Regulator The DRV10983 includes a step-down voltage regulator that can be operated as either a switching buck style regulator or as a linear regulator (see Figure 4). The regulator output voltage can be configured by register bit VregSel. When VregSel = 0, the regulator output voltage is 5 V, and when VregSel = 1, the regulator output voltage is 3.3 V. If the step-down regulator is configured as buck style, refer to IREG_MAX in the Electrical Characteristics to determine the amount of current provided for external load. If the step-down regulator is configured as linear mode, it is used for the device internal circuit only. Buck Regulator Linear Regulator Figure 4. Step-Down Regulator Configurations 9.3.1.2 3.3-V and 1.8-V LDO The DRV10983 includes a 3.3-V LDO and an 1.8-V LDO. The 1.8-V LDO is for internal circuit only. The 3.3-V LDO is mainly for internal circuits, but can also drive external loads not to exceed IV3P3_MAX listed in the Electrical Characteristics . For example, it can work as a pullup voltage for the FG, DIR, SDA, and SCL interface. Both V1P8 and V3P3 capacitor must be connected to GND. 9.3.2 Protection Circuits 9.3.2.1 Thermal Shutdown The DRV10983 has a built-in thermal shutdown function, which shuts down the device when junction temperature is more than TSDN ˚C and recovers operating conditions when junction temperature falls to TSDN – TSDN_HYS˚C. The OverTemp status bit (address 0x10 bit 7) is set during thermal shutdown. 9.3.2.2 UVLO The DRV10983 has a built-in UVLO function block. The hysteresis of UVLO threshold is VUVLO-HYS. The device is locked out when VCC is down to VUVLO_F and woke up at VUVLO_R. 9.3.2.3 Current Protection The overcurrent shutdown function acts to protect the device if the current, as measured from the FETs, exceeds the IOC-limit threshold. It protects the device from phase to phase short-circuit conditions; the DRV10983 places the output drivers into a high-impedance state and maintains this condition until the overcurrent is no longer present. The OverCurr status bit (address 0x10 bit 5) is set. The DRV10983 also provides acceleration current limit and lock detection current limit functions to protect the device and motor (see Current Limit and Lock Detect and Fault Handling ). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |