80 / 88 page ![]() RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet DS20005251A-page 80 2013 Microchip Technology Inc. Appendix A Look Up Table Operation The EMC2113 uses a look-up table to apply a user-programmable fan control profile based on measured temperature to the fan driver. In this look-up table, each temperature channel is allowed to control the fan drive output independently (or jointly) by programming up to eight pairs of temperature and drive setting entries. The user programs the look-up table based on the desired operation. If the RPM-based Fan Speed Control Algorithm is to be used (see Section 6.6), then the user must program an RPM target for each temperature setting of interest. Alternately, if the RPM-based Fan Speed Control Algorithm is not to be used, then the user must program a drive setting for each temperature setting of interest. If the measured temperature on the External Diode channel meets or exceeds any of the temperature thresholds for any of the channels, the fan output will be automatically set to the desired setting corresponding to the exceeded temperature. In cases where multiple temperature channel thresholds are exceeded, the highest fan drive setting will take precedence. When the measured temperature drops to a point below a lower threshold minus the hysteresis value, the fan output will be set to the corresponding lower set point. The following sections show examples of how the Look Up Table is used and configured. Each Look Up Table Example uses the Fan 1 Look Up Table Registers configured as shown in Table A.1. A.1 Example #1 This example does not use the RPM-based Fan Speed Control Algorithm. Instead, the Look Up Table is configured to directly set a PWM setting based on the temperature of four of its measured inputs. The configuration is set as shown in Table A.2, "Look Up Table Example #1 Configuration". Once configured, the Look Up Table is loaded as shown in Section Table A.3, "Fan Speed Control Table Example #1". Table A.4 shows three temperature configurations using the settings in Table A.3 and the final PWM output drive setting that the Look Up Table will select. Table A.1 Look Up Table Format STEP TEMP 1 TEMP 2 TEMP 3 TEMP 4 LUT DRIVE 1 LUT Temp 1 Setting 1 (52h) LUT Temp 2 Setting 1 (53h) LUT Temp 3 Setting 1 (54h) LUT Temp 4 Setting 1 (55h) LUT Drive Setting 1 (51h) 2 LUT Temp 1 Setting 2 (57h) LUT Temp 2 Setting 2 (58h) LUT Temp 3 Setting 2 (59h) LUT Temp 4 Setting 2 (5Ah) LUT Drive Setting 2 (56h) 3 LUT Temp 1 Setting 3 (5Ch) LUT Temp 2 Setting 3 (5Dh) LUT Temp 3 Setting 3 (5Eh) LUT Temp 4 Setting 3 (5Fh) LUT Drive Setting 3 (5Bh) 4 LUT Temp 1 Setting 4 (61h) LUT Temp 2 Setting 4 (62h) LUT Temp 3 Setting 4 (63h) LUT Temp 4 Setting 4 (64h) LUT Drive Setting 4 (60h) 5 LUT Temp 1 Setting 5 (66h) LUT Temp 2 Setting 5 (67h) LUT Temp 3 Setting 5 (68h) LUT Temp 4 Setting 5 (69h) LUT Drive Setting 5 (65h) 6 LUT Temp 1 Setting 6 (6Bh) LUT Temp 2 Setting 6 (6Ch) LUT Temp 3 Setting 6 (6Dh) LUT Temp 4 Setting 6 (6Eh) LUT Drive Setting 6 (6Ah) 7 LUT Temp 1 Setting 7 (70h) LUT Temp 2 Setting 7 (71h) LUT Temp 3 Setting 7 (72h) LUT Temp 4 Setting 7 (73h) LUT Drive Setting 7 (6Fh) 8 LUT Temp 1 Setting 8 (75h) LUT Temp 2 Setting 8 (76h) LUT Temp 3 Setting 8 (77h) LUT Temp 4 Setting 8 (78h) LUT Drive Setting 8 (74h) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |