| 数据搜索系统,热门电子元器件搜索 |
|
HT306/DF60-1012 数据表(PDF) 9 Page - Hirose Electric |
|
|
|||||||||||||||||||||||||||||
HT306/DF60-1012 数据表(HTML) 9 Page - Hirose Electric |
|
9 / 12 page ![]() 9 DF60 Series ●65A 10.16mm pitch Wire-to-Board Connectors for Internal Power Supply(UL, C-UL, TÜV certified product) BRemoving Contacts BPrecautions for use BRated values BOperating environment ●Contact extraction tool: precision screwdriver (flathead screwdriver with 1.4mm in width across flats) ●For Crimp contacts: DF60-8SC(F)A, DF60-1012SC(F)A, DF60-8PC(F)A, DF60-1012PC(F)A ●Procedure Sectioned drawing of the housing 1. The connector could be damaged if it is pulled out forcibly. When it is hard to pull out, push it in slightly first and then depress the lock and un- mate. 2. When thick, short sections of wire are used, the connector could be deformed due to the force of the wires’ position. Route cables in such a way that they do not twist when being installed. 3. Make sure to turn off the power when mating or un-mating the connector. 4. Please do not touch any area around the contact part with your hand when the power is on; it could be very dangerous. 5. Please contact our Sales Department about the assembly procedure and the instruction manual. Please avoid using the device above the rated values. Also, do not insert or pull out energized or “ live” wires. Please contact us if you are designing this connector into environmental conditions where high and low temperatures are repeated. Due to any previous repairs, the strength of the lance could have been compromised. Hirose recommends the use of a new crimp housing to assure proper performance. 1. After unmating the parts, position the screwdriver to raise the lance as shown in the illustration. 2. The lance needs to be raised sufficiently to allow the terminated wire to slip past it. The lance needs to be held up while at the same time pulling on the wire. Caution Please be very careful when removing the contact work so that you don’t become injured by the protruding part of the crimp contact. Precision screwdriver Before attempting to remove any contacts, make sure that the power is switched off and the system is de-energized. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |