3 / 10 page ![]() www.sensirion.com v5 February 2013 3/10 Table 2: Additional sensor specifications. Media Air, N2 – for other gases contact Sensirion AG. Operating Conditions: - Temperature - Humidity -10 °C … +60 °C / 14°F … 140 °F non-condensing Ambient storage conditions1 -40 °C … +80 °C / -40°F … 176 °F Orientation sensitivity below resolution Response time 40 ms (for faster response time contact Sensirion) Admissible overpressure (short term) 1 bar (14.5 PSI) Burst Pressure Capability 2 bar (29 PSI) Weight 14 g Protection Class IP 20 Wetted materials Glass (silicon nitride, silicon oxide), Silicon, PPS (Polyphenylene Sulfide), PEEK (Polyetheretherketone), FR4, Silicone as static sealing, Epoxy, Gold Gas flow through sensor see Figure 6. Lead free The SDP1000 family is fully RoHS compliant (1) For maximum 2 weeks 1.1 Temperature Compensation The SDP1000 / SDP2000 differential pressure sensors feature a sophisticated built-in temperature compensation circuit. The temperature is measured on the CMOSens chip by means of a PTAT bandgap reference temperature sensor. Its data is fed into a compensation circuit which is also integrated on the CMOSens® sensor chip. No external temperature compensation is therefore required. 1.2 Altitude Correction The SDP1000 / SDP2000 differential pressure sensors achieve their unsurpassed performance by using a dynamic measurement principle, i.e. an applied differential pressure forces a small air flow through the sensor. This results in a dependence of the indicated differential pressure on the ambient air density. While the temperature effect is compensated (see Paragraph 1.1) the altitude above sea level has an influence on the SDP1000 / SDP2000 output. If desired, this effect can be compensated by a correction factor according to the following equation: Dpeff = Dpsensor * Pcal / Pamb where Dpeff is the effective differential pressure, Dpsensor the differential pressure indicated by the SDP1000 / SDP2000, Pcal the absolute pressure during calibration (966 mbar) and Pamb the actual ambient absolute pressure. This leads to the following correction factors: Table 3: Altitude correction factors. Altitude [meter] Ambient Pressure (Pamb) [mbar] Correction Factor Pcal / Pamb 0 1013 0.95 250 984 0.98 425 966 1.00 500 958 1.01 750 925 1.04 1500 842 1.15 2250 766 1.26 3000 697 1.38 Example: The SDP1000 is used at 750 m above sea level. The output of the SDP1000 shows 0.5 V, which corresponds to Dpsensor = 33.3 Pa. Taking into account the correction factor Pcal / Pamb = 1.04 the effective differential pressure Dpeff is 33.3 Pa * 1.04 = 34.6 Pa. Note: In many HVAC applications such as filter monitoring, fan/ventilator control or air flow measurement the described effect is actually welcome since at the end the mass flow and not volume flow is the effective value to control. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |