| 数据搜索系统,热门电子元器件搜索 |
|
CS10.481 数据表(PDF) 11 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CS10.481 数据表(HTML) 11 Page - PULS GmbH |
|
11 / 26 page ![]() CS10.481 C-Line 48V, 5A, SINGLE PHASE INPUT 9. LIFETIME EXPECTANCY AND MTBF AC 100V AC 120V AC 230V Lifetime expectancy*) 97 000h 106 000h 122 000h at 48V, 2.5A and 40°C 275 000h*) 299 000h*) 346 000h*) at 48V, 2.5A and 25°C 45 000h 60 000h 96 000h at 48V, 5A and 40°C 128 000h 171 000h*) 272 000h*) at 48V, 5A and 25°C 33 000h 42 000h 63 000h at 48V, 6A and 40°C 93 000h 119 000h 179 000h*) at 48V, 6A and 25°C MTBF**) SN 29500, IEC 61709 627 000h 653 000h 830 000h at 48V, 5A and 40°C 536 000h 558 000h 709 000h at 48V, 6A and 40°C 1 060 000h 1 104 000h 1 403 000h at 48V, 5A and 25°C MTBF**) MIL HDBK 217F 459 000h 450 000h 475 000h at 48V, 5A and 40°C; Ground Benign GB40 413 000h 406 000h 426 000h at 48V, 6A and 40°C; Ground Benign GB40 655 000h 642 000h 659 000h at 48V, 5A and 25°C; Ground Bening GB25 *) The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years (131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices. **) MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it can not be determined if the failed unit has been running for 50 000h or only for 100h. 10. FUNCTIONAL DIAGRAM Fig. 10-1 Functional diagram + + - - V OUT Input Fuse & Input Filter Output Voltage Regulator Power Converter Output Filter DC ok L N Output Over- Voltage Input Rectifier & Inrush Limiter Protection 115/230V Auto Select Jul. 2015 / Rev. 2.0 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 11/26 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |