10 / 22 page ![]() CT10.241 C-Series 24V, 10A, THREE PHASE INPUT 11. TERMINALS AND WIRING Input Output Type screw terminals screw terminals Solid wire 0.5-6mm2 0.5-6mm2 Stranded wire 0.5-4mm2 0.5-4mm2 American Wire Gauge 20-10 AWG 20-10 AWG Wire stripping length 7mm / 0.275inch 7mm / 0.275inch Screwdriver 3.5mm slotted or Pozidrive No 2 3.5mm slotted or Pozidrive No 2 Recommended tightening torque 0.8Nm, 7lb.in 0.8Nm, 7lb.in Instructions: a) Use appropriate copper cables that are designed for an operating temperature of: 60°C for ambient up to 45°C and 75°C for ambient up to 60°C minimum. b) Follow national installation codes and installation regulations! c) Ensure that all strands of a stranded wire enter the terminal connection! d) Up to two stranded wires with the same cross section are permitted in one connection point (except PE wire). e) Do not use the unit without PE connection. f) Screws of unused terminal compartments should be securely tightened. g) Ferrules are allowed, but not required 12. RELIABILITY 3-Phase operation 3AC 400V 3AC 480V Lifetime expectancy *) 54 000h 62 000h at 24V, 10A and 40°C 133 000h 134 000h at 24V, 5A and 40°C 151 000h 176 000h at 24V, 10A and 25°C MTBF **) SN 29500, IEC 61709 975 000h 985 000h at 24V, 10A and 40°C 1 706 000h 1 723 000h at 24V, 10A and 25°C MTBF **) MIL HDBK 217F 445 000h 429 000h at 24V, 10A and 40°C; Ground Benign GB40 584 000h 427 000h at 24V, 10A and 25°C; Ground Benign GB25 Operation only on 2 legs of a three phase system 2AC 400V 2AC 480V Lifetime expectancy *) 48 000h 58 000h at 24V, 10A and 40°C 134 000h 145 000h at 24V, 5A and 40°C 135 000h 164 000h at 24V, 10A and 25°C MTBF **) SN 29500, IEC 61709 925 000h 939 000h at 24V, 10A and 40°C 1 633 000h 1 656 000h at 24V, 10A and 25°C MTBF **) MIL HDBK 217F 437 000h 423 000h at 24V, 10A and 40°C; Ground Benign GB40 573 000h 556 000h at 24V, 10A and 25°C; Ground Benign GB25 *) The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The prediction model allows only a calculation of up to 15 years from date of shipment. **) MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. Jan. 2010 / Rev. 1.3 DS-CT10.241-EN All parameters are specified at 24V, 10A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 10/22 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |