| 数据搜索系统,热门电子元器件搜索 |
|
PCI7421 数据表(PDF) 43 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PCI7421 数据表(HTML) 43 Page - Texas Instruments |
|
43 / 298 page ![]() 2−17 Table 2−8. PCI Interface Control Terminals Internal pullup/pulldown resistors and pin strapping are not applicable for the PCI interface control terminals. TERMINAL DESCRIPTION I/O INPUT OUTPUT POWER EXTERNAL NAME NO. DESCRIPTION I/O TYPE INPUT OUTPUT POWER RAIL EXTERNAL COMPONENTS DEVSEL N08 PCI device select. The controller asserts DEVSEL to claim a PCI cycle as the target device. As a PCI initiator on the bus, the controller monitors DEVSEL until a target responds. If no target responds before timeout occurs, then the controller terminates the cycle with an initiator abort. I/O PCII3 PCIO3 VCCP Pullup resistor per PCI specification FRAME V07 PCI cycle frame. FRAME is driven by the initiator of a bus cycle. FRAME is asserted to indicate that a bus transaction is beginning, and data transfers continue while this signal is asserted. When FRAME is deasserted, the PCI bus transaction is in the final data phase. I/O PCII3 PCIO3 VCCP Pullup resistor per PCI specification GNT T02 PCI bus grant. GNT is driven by the PCI bus arbiter to grant the controller access to the PCI bus after the current data transaction has completed. GNT may or may not follow a PCI bus request, depending on the PCI bus parking algorithm. I PCII3 VCCP IDSEL W05 Initialization device select. IDSEL selects the controller during configuration space accesses. IDSEL can be connected to one of the upper 24 PCI address lines on the PCI bus. I PCII3 VCCP IRDY U07 PCI initiator ready. IRDY indicates the ability of the PCI bus initiator to complete the current data phase of the transaction. A data phase is completed on a rising edge of PCLK where both IRDY and TRDY are asserted. Until IRDY and TRDY are both sampled asserted, wait states are inserted. I/O PCII3 PCIO3 VCCP Pullup resistor per PCI specification PERR V08 PCI parity error indicator. PERR is driven by a PCI controller to indicate that calculated parity does not match PAR when PERR is enabled through bit 6 of the command register (PCI offset 04h, see Section 4.4). I/O PCII3 PCIO3 VCCP Pullup resistor per PCI specification REQ U01 PCI bus request. REQ is asserted by the controller to request access to the PCI bus as an initiator. O PCIO3 VCCP SERR U08 PCI system error. SERR is an output that is pulsed from the controller when enabled through bit 8 of the command register (PCI offset 04h, see Section 4.4) indicating a system error has occurred. The controller need not be the target of the PCI cycle to assert this signal. When SERR is enabled in the command register, this signal also pulses, indicating that an address parity error has occurred on a CardBus interface. O PCIO3 VCCP Pullup resistor per PCI specification STOP W08 PCI cycle stop signal. STOP is driven by a PCI target to request the initiator to stop the current PCI bus transaction. STOP is used for target disconnects and is commonly asserted by target devices that do not support burst data transfers. I/O PCII3 PCIO3 VCCP Pullup resistor per PCI specification TRDY R08 PCI target ready. TRDY indicates the ability of the primary bus target to complete the current data phase of the transaction. A data phase is completed on a rising edge of PCLK when both IRDY and TRDY are asserted. Until both IRDY and TRDY are asserted, wait states are inserted. I/O PCII3 PCIO3 VCCP Pullup resistor per PCI specification |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |