Back Button L9659 Datasheet HTML 19Page - STMicroelectronics L9659 Datasheet HTML 20Page - STMicroelectronics L9659 Datasheet HTML 21Page - STMicroelectronics L9659 Datasheet HTML 22Page - STMicroelectronics L9659 Datasheet HTML 23Page - STMicroelectronics L9659 Datasheet HTML 24Page - STMicroelectronics L9659 Datasheet HTML 25Page - STMicroelectronics L9659 Datasheet HTML 26Page - STMicroelectronics L9659 Datasheet HTML 27Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 51 page
background image
L9659
Functional description
Doc ID 022048 Rev 2
23/51
Figure 7.
Deployment drivers diagram
Driver activation
The firing of a squib driver requires the appropriate FEN function to be active and two
separate sixteen bit writes be made over the SPI. The FEN function is defined as the result
of the FENx pin OR’d with the internal FENx latch. The FENx pin going high initiates the
FEN function. With the FEN 1 function being active and the appropriate Arm and Fire
commands sent then Squib_0 & 1 drivers would be activated. With the FEN 2 function being
active and the appropriate Arm and Fire commands sent then Squib_2 & 3 drivers would be
activated. With the FEN 3 function being active and the appropriate Arm and Fire
commands sent then Squib_4 & 5 drivers would be activated. With the FEN 4 function being
active and the appropriate Arm and Fire commands sent then Squib_6 & 7 drivers would be
activated.
The first write is to ARM the drivers in preparation of receiving the fire command. The Arm
command will stop on all channels any diagnostics that are active. Any combination of
squibs can be armed. The second write is a FIRE command that must directly follow the
Arm command and will activate the desired driver pairs assuming the FEN function is valid.
If there is a parity mismatch the data bits will be ignored and the squib drivers will not have
their status changed, and the two write sequence must then be started again. If there is a
mismatch in channels selected then only those channels selected in both the Arm and Fire
commands will be activated.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com