| 数据搜索系统,热门电子元器件搜索 |
|
STUSB1600 数据表(PDF) 16 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STUSB1600 数据表(HTML) 16 Page - STMicroelectronics |
|
16 / 69 page ![]() Features description STUSB1600 16/69 DocID028937 Rev 1 “Type-C attached state” refers to the Type-C FSM states as defined in the USB Type-C standard specification and as described in the I2C register CC_OPERATION_STATUS (see Section 5.1: Register description). “VDD pin monitoring” is valid only in source power role. Activation of the UVLO and OVLO threshold detections can be done through NVM programming (see Section 6: Start-up configuration) and also by software through the I2C interface (see Section 5.1: Register description). When the UVLO and/or OVLO threshold detection is activated, the VBUS_EN_SRC pin is asserted only if the device is attached and the valid threshold conditions on VDD are met. Once the VBUS_EN_SRC pin is asserted, the VBUS monitoring is done on VBUS_SENSE pin instead of the VDD pin. “VBUS_SENSE pin monitoring” relies, by default, on a valid VBUS voltage range. The voltage range condition can be disabled to consider UVLO threshold detection instead. The monitoring condition of the VBUS voltage can be changed through NVM programming (see Section 6: Start-up configuration) and also by software through the I2C interface (see Section 5.1: Register description). The VBUS_EN_SRC pin is maintained asserted as long as the device is attached and a valid voltage condition on the VBUS is met. Table 8. Conditions for VBUS power path assertion in sink power role Pin Electrical value Operation conditions Comment Type-C attached state VDD pin monitoring VBUS_SENSE pin monitoring VBUS_EN_SNK 0 Attached.SNK or Debug Accessory.SNK Not applicable VBUS is within valid voltage range if VBUS _VALID_RANGE enabled or VBUS > UVLO if VBUS _VALID_RANGE disabled The signal is asserted only if all the valid operation conditions are met HiZ Any other state Not applicable VBUS is out of valid voltage range if VBUS _VALID_RANGE enabled or VBUS < UVLO if VBUS _VALID_RANGE disabled The signal is de-asserted when at least one non valid operation condition is met |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |