10 / 20 page ![]() 1.0 Functional Description (Continued) available in two 8-bit registers: Temperature Digital Output Binary Hex +125˚C 0111 1101 0000 0000 7D00h +25˚C 0001 1001 0000 0000 1900h +1˚C 0000 0001 0000 0000 0100h +0.125˚C 0000 0000 0010 0000 0020h 0˚C 0000 0000 0000 0000 0000h −0.125˚C 1111 1111 1110 0000 FFE0h −1˚C 1111 1111 0000 0000 FF00h −25˚C 1110 0111 0000 0000 E700h −55˚C 1100 1001 0000 0000 C900h Local Temperature data is represented by an 8-bit, two’s complement byte with an LSB (Least Significant Bit) equal to 1˚C: Temperature Digital Output Binary Hex +125˚C 0111 1101 7Dh +25˚C 0001 1001 19h +1˚C 0000 0001 01h 0˚C 0000 0000 00h −1˚C 1111 1111 FFh −25˚C 1110 0111 E7h −55˚C 1100 1001 C9h 1.7 OPEN-DRAIN OUTPUTS The SMBData, ALERT and T_CRIT_A outputs are open- drain outputs and do not have internal pull-ups. A “high” level will not be observed on these pins until pull-up current is provided by some external source, typically a pull-up resis- tor. Choice of resistor value depends on many system fac- tors but, in general, the pull-up resistor should be as large as possible. This will minimize any internal temperature reading errors due to internal heating of the LM89. The maximum resistance of the pull-up to provide a 2.1V high level, based on LM89 specification for High Level Output Current with the supply voltage at 3.0V, is 82k Ω(5%) or 88.7kΩ(1%). 1.8 DIODE FAULT DETECTION The LM89 is equipped with operational circuitry designed to detect fault conditions concerning the remote diode. In the event that the D+ pin is detected as shorted to V DD or floating, the Remote Temperature High Byte (RTHB) register is loaded with +127˚C, the Remote Temperature Low Byte (RTLB) register is loaded with 0, and the OPEN bit (D2) in the status register is set. As a result, if the Remote T_CRIT setpoint register (RCS) is set to a value less than +127˚C the ALERT and T_Crit output pins will be pulled low, if the Alert Mask and T_Crit Mask are disabled. If the Remote HIGH Setpoint High Byte Register (RHSHB) is set to a value less than +127˚C then ALERT will be pulled low, if the Alert Mask is disabled. The OPEN bit itself will not trigger and ALERT. In the event that the D+ pin is shorted to ground or D−, the Remote Temperature High Byte (RTHB) register is loaded with −128˚C (1000 0000) and the OPEN bit (D2) in the status register will not be set. Since operating the LM89 at −128˚C is beyond it’s operational limits, this temperature reading represents this shorted fault condition. If the value in the Remote Low Setpoint High Byte Register (RLSHB) is more than −128˚C and the Alert Mask is disabled, ALERT will be pulled low. Remote diode temperature sensors that have been previ- ously released and are competitive with the LM89 output a code of 0˚C if the external diode is short-circuited. This change is an improvement that allows a reading of 0˚C to be truly interpreted as a genuine 0˚C reading and not a fault condition. 1.9 COMMUNICATING WITH THE LM89 The data registers in the LM89 are selected by the Com- mand Register. At power-up the Command Register is set to “00”, the location for the Read Local Temperature Register. The Command Register latches the last location it was set to. Each data register in the LM89 falls into one of four types of user accessibility: 1. Read only 2. Write only 3. Read/Write same address 4. Read/Write different address A Write to the LM89 will always include the address byte and the command byte. A write to any register requires one data byte. Reading the LM89 can take place either of two ways: 1. If the location latched in the Command Register is cor- rect (most of the time it is expected that the Command Register will point to one of the Read Temperature Reg- isters because that will be the data most frequently read from the LM89), then the read can simply consist of an address byte, followed by retrieving the data byte. 2. If the Command Register needs to be set, then an address byte, command byte, repeat start, and another address byte will accomplish a read. The data byte has the most significant bit first. At the end of a read, the LM89 can accept either acknowledge or No Acknowledge from the Master (No Acknowledge is typically used as a signal for the slave that the Master has read its last byte). It takes the LM89 31.25ms to measure the tem- perature of the remote diode and internal diode. When re- trieving all 10 bits from a previous remote diode temperature measurement, the master must insure that all 10 bits are from the same temperature conversion. This may be achieved by using one-shot mode or by setting the conver- sion rate and monitoring the busy bit such that no conversion occurs in between reading the MSB and LSB of the last temperature conversion. www.national.com 10 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |