| 数据搜索系统,热门电子元器件搜索 |
|
LM89 数据表(PDF) 14 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM89 数据表(HTML) 14 Page - National Semiconductor (TI) |
|
14 / 20 page ![]() 2.0 LM89 Registers (Continued) Command Select Address Power-On-Default State Register Name Register Function Read Address <P7:P0> hex Write Address <P7:P0> hex <D7:D0> binary <D7:D0> decimal 12h 12h 0000 0000 0 RTOLB Remote Temperature Offset Low Byte 13h 13h 0000 0000 0 RHSLB Remote HIGH Setpoint Low Byte 14h 14h 0000 0000 0 RLSLB Remote LOW Setpoint Low Byte 19h 19h 0110 1110 110 RCS Remote T_CRIT Setpoint 20h 20h 0101 0101 85 LCS Local T_CRIT Setpoint 21h 21h 0000 1010 10 TH T_CRIT Hysteresis B0h-BEh B0h-BEh Manufacturers Test Registers BFh BFh 0000 0000 0 RDTF Remote Diode Temperature Filter FEh NA 0000 0001 1 RMID Read Manufacturer’s ID FFh NA LM89 0011 0001 LM89-1 0011 0100 49 52 RDR Read Stepping or Die Revision Code 2.2 LOCAL and REMOTE TEMPERATURE REGISTERS (LT, RTHB, RTLB) (Read Only Address 00h, 01h): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value SIGN 64 32 16 8 4 2 1 For LT and RTHB D7–D0: Temperature Data. LSB = 1˚C. Two’s complement format. (Read Only Address 10h): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value 0.5 0.25 0.125 0000 0 For RTLB D7–D5: Temperature Data. LSB = 0.125˚C. Two’s complement format. The maximum value available from the Local Temperature register is 127; the minimum value available from the Local Temperature register is -128. The maximum value available from the Remote Temperature register is 127.875; the minimum value available from the Remote Temperature registers is −128.875. 2.3 STATUS REGISTER (SR) (Read Only Address 02h): D7 D6 D5 D4 D3 D2 D1 D0 Busy LHIGH LLOW RHIGH RLOW OPEN RCRIT LCRIT Power up default is with all bits “0” (zero). D0: LCRIT: When set to “1” indicates a Local Critical Temperature alarm. D1: RCRIT: When set to “1” indicates a Remote Diode Critical Temperature alarm. D2: OPEN: When set to “1” indicates a Remote Diode disconnect. D3: RLOW: When set to “1” indicates a Remote Diode LOW Temperature alarm D4: RHIGH: When set to “1” indicates a Remote Diode HIGH Temperature alarm. D5: LLOW: When set to “1” indicates a Local LOW Temperature alarm. D6: LHIGH: When set to “1” indicates a Local HIGH Temperature alarm. D7: Busy: When set to “1” ADC is busy converting. 2.4 CONFIGURATION REGISTER (Read Address 03h /Write Address 09h): D7 D6 D5 D4 D3 D2 D1 D0 ALERT mask RUN/STOP 0 Remote T_CRIT_A mask 0 Local T_CRIT_A mask 0 Fault Queue Power up default is with all bits “0” (zero) D7: ALERT mask: When set to “1” ALERT interrupts are masked. www.national.com 14 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |