| 数据搜索系统,热门电子元器件搜索 |
|
CP20.241-R1 数据表(PDF) 17 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP20.241-R1 数据表(HTML) 17 Page - PULS GmbH |
|
17 / 30 page ![]() CP20.241-R1, CP20.241-R2, CP20.241-R3 CP-Series 24V, 20A, SINGLE PHASE INPUT June 2017 / Rev. 0.1 DS-CP20.241-R2-EN All parameters are typical values specified at 20A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 17/30 P R E L I M I N A R Y Switching Frequencies The power supply has three converters included. Two converters have a fixed switching frequency and one operates with a variable switching frequency. Switching frequency 1 110kHz PFC converter Switching frequency 2 110kHz to 140kHz Main converter, output power dependent Switching frequency 3 60kHz Auxiliary converter 17. ENVIRONMENT Operational temperature1) -40°C to +70°C (-40°F to 158°F) See also Fig. 17-1 Storage temperature -40°C to +85°C (-40°F to 185°F) For storage and transportation Output de-rating 6.4W/°C 12W/°C +45°C to +60°C (113°F to 140°F), see Fig. 17-1 +60°C to +70°C (140°F to 158°F), see Fig. 17-1 The de-rating is not hardware controlled. The customer has to take care by himself to stay below the de-rated current limits in order not to overload the unit. Humidity2) 5 to 95% r.h. IEC 60068-2-30 Vibration sinusoidal 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g3) 2 hours / axis3) IEC 60068-2-6 Shock 30g 6ms, 20g 11ms3) 3 bumps / direction, 18 bumps in total IEC 60068-2-27 Altitude 0 to 2000m (0 to 6 560ft) Without any restrictions 2000 to 6000m (6 560 to 20 000ft) Reduce output current or ambient temperature, see Fig. 17-2 IEC 62477-1, overvoltage category II Altitude de-rating 30W/1000m or 5°C/1000m Above 2000m (6500ft), see Fig. 17-2 Over-voltage category III IEC 62477-1, altitudes up to 2000m II For altitudes from 2000m to 6000m Degree of pollution 2 IEC 62477-1, not conductive LABS compatibility The unit does not release any silicone or other LABS-critical substances and is suitable for use in paint shops. Corrosive gases ISA-71.04-1985, Severity Level G3, IEC 60068-2-60 Test Ke Method 4 Audible noise Some audible noise may be emitted from the power supply during no load, overload or short circuit. 1) Operational temperature is the same as the ambient or surrounding temperature and is defined as the air temperature 2cm below the unit. 2) Do not energize while condensation is present 3) Tested in combination with DIN-Rails according to EN 60715 with a height of 15mm and a thickness of 1.3mm and standard orientation. Fig. 17-1 Output current vs. ambient temp. Fig. 17-2 Output current vs. altitude Allowed Output Current 0 -40 020 40 70°C 4A 8A 12A 16A 20A 24A 60 B A A... continuous B... short term (max. 5s) 0 0 2000m 4000m 6000m 4A 8A 12A 16A 20A 24A Allowable Output Current Ambient Temperature Altitude B C A... Tamb < 60°C B... Tamb < 50°C C... Tamb < 40°C D... Short term A D |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |