12 / 15 page ![]() Date: 02/24/05 SP3282EB Intelligent +2.35V to +5.5V RS-232 Transceivers © Copyright 2005 Sipex Corporation 12 The circuit model in Figures 18 and 19 represent the typical ESD testing circuit used for all three methods. The CS is initially charged with the DC power supply when the first switch (SW1) is on. Now that the capacitor is charged, the second switch (SW2) is on while SW1 switches off. The voltage stored in the capacitor is then applied through RS, the current limiting resistor, onto the device under test (DUT). In ESD tests, the SW2 switch is pulsed so that the device under test receives a duration of voltage. For the Human Body Model, the current limiting resistor (R S) and the source capacitor (CS) are 1.5k Ω an 100pF, respectively. For IEC-1000-4-2, the current limiting resistor (R S) and the source capacitor (C S) are 330Ω an 150pF, respectively. Figure 18. ESD Test Circuit for Human Body Model RC CS RS SW1 SW2 RC Device Under Test DC Power Source CS RS SW1 SW2 Figure 20. ESD Test Waveform for IEC1000-4-2 Figure 19. ESD Test Circuit for IEC1000-4-2 RS and RV add up to 330 add up to 330Ω for IEC1000-4-2. RS and RV add up to 330Ω for IEC1000-4-2. Contact-Discharge Module RV RC CS RS SW1 SW2 RC Device Under Test DC Power Source CS RS SW1 SW2 RV Contact-Discharge Module devised to reduce the unpredictability of the ESD arc. The discharge current rise time is constant since the energy is directly transferred without the air-gaparc. Insituationssuchashandheldsystems, the ESD charge can be directly discharged to the equipment from a person already holding the equipment. The current is transferred on to the keypadortheserialportoftheequipmentdirectlyand then travels through the PCB and finally to the IC. The higher C S value and lower R S value in the IEC1000-4-2 model are more stringent than the Human Body Model. The larger storage capacitor injects a higher voltage to the test point when SW2 is switched on. The lower current limiting resistor increases the current charge onto the test point. t=0ns t=30ns 0A 15A 30A t ➙ |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |