21 / 29 page ![]() AD7927 Data Sheet Rev. D | Page 20 of 28 AUTO SHUTDOWN (PM1 = 0, PM0 = 1) In this mode, the AD7927 automatically enters shutdown at the end of each conversion when the control register is updated. When the part is in shutdown, the track-and-hold is in hold mode. Figure 23 shows the general diagram of the operation of the AD7927 in this mode. In shutdown mode all internal circuitry on the AD7927 is powered down. The part retains information in the control register during shutdown. The AD7927 remains in shutdown until the next CS falling edge it receives. On this CS falling edge, the track-and-hold that was in hold while the part was in shutdown returns to track. Wake-up time from auto shutdown is 1 μs maximum, and the user should ensure that 1 μs has elapsed before attempting a valid conversion. When running the AD7927 with a 20 MHz clock, one dummy 16 SCLK transfer should be sufficient to ensure the part is fully powered up. During this dummy transfer, the contents of the control register should remain unchanged; therefore, the WRITE bit should be 0 on the DIN line. Depending on the SCLK frequency used, this dummy transfer may affect the achievable throughput rate of the part, with every other data transfer being a valid conversion result. If, for example, the maximum SCLK frequency of 20 MHz was used, the auto shutdown mode could be used at the full throughput rate of 200 kSPS without affecting the throughput rate at all. Only a portion of the cycle time is taken up by the conversion time and the dummy transfer for wake-up. In this mode, the power consumption of the part is greatly reduced with the part entering shutdown at the end of each conversion. When the control register is programmed to move into auto shutdown, it does so at the end of the conversion. The user can move the ADC in and out of the low power state by controlling the CS signal. 1 SCLK DOUT DIN 16 1 1 16 DUMMY CONVERSION CHANNEL IDENTIFIER BITS + CONVERSION RESU LT INVALID DATA CHANNEL IDENTIFIER BITS + CONVERSION RESU LT 12 12 12 CONTROL REGISTER IS LOADED ON THE FIRST 12 CLOCKS, PM1 = 0, PM0 = 1 CONTROL REGISTER SHOULD NOT CHANGE, WRITE BIT = 0 TO KEEP PART IN THIS MODE, LOAD PM1 = 0, PM0 = 1 IN CONTROL REGISTER OR SET WRITE BIT = 0 DATA INTO CONTROL/SHADOW REGISTER DATA IN TO CONTROL/SHADOW REGISTER 16 CS PART ENTERS SHUTDOWN ON CS RISING EDGE AS PM1 = 0, PM0 = 1 PART BEGINS TO POWER UP ON CS FALLING EDGE PART IS FULLY POWERED UP PART ENTERS SHUTDOWN ON CS RISING EDGE AS PM1 = 0, PM0 = 1 Figure 23. Auto Shutdown Mode Operation |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |