| 数据搜索系统,热门电子元器件搜索 |
|
PIP3221-DC 数据表(PDF) 4 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PIP3221-DC 数据表(HTML) 4 Page - NXP Semiconductors |
|
4 / 16 page ![]() Philips Semiconductors PIP3221-DC Dual channel high-side TOPFET™ Product data Rev. 01 — 20 February 2004 4 of 16 9397 750 12361 © Koninklijke Philips Electronics N.V. 2004. All rights reserved. 5. Functional description A diagnostic status ensures faster fault detection. Active current limit is combined with a soft latched short circuit protection feature in order to protect the device in the event of a short circuit. Thermal shutdown for high temperature conditions has an automatic restart at a lower temperature so providing protection against excessive power dissipation. Active clamping protects the device against low energy spikes. Undervoltage lockout means the device shuts down for low battery voltages, thus avoiding faulty operation. Overvoltage shutdown in the on-state protects a load such as a lamp filament from potentially destructive voltage spikes. [1] The status will continue to indicate OT (even if the input goes LOW) until the device cools below the reset threshold temperature. See “Overtemperature protection” characteristics in Table 7 “Static characteristics”. Table 4: Truth table Abbreviations: L = logic LOW; H = logic HIGH; X = don’t care; 0 = condition not present; 1 = condition present; UV = undervoltage; OV = overvoltage; OC = open circuit load; SC = short circuit; OT = overtemperature [1]. Input Supply Load 1 Load 2 Load output Status Operating mode 1 2 UV OV OC SC OT OC SC OT 1 2 L L 0 X 0 X X 0 X X OFF OFF H both off & normal L L 0 X 1 XXXXX OFF OFF L both off, one/both OC or shorted to VS or battery; Figure 10 L H 0 X 1 X X 0 0 0 OFF ON L one off & OC, with other on & normal H L00000000 ON OFF H one on & normal, with other off & normal H H 00000000 ON ON H both on & normal H X 1 0 X X X 0 X X OFF OFF H supply undervoltage lockout H X 0 1 X 0 0 X 0 0 OFF OFF H supply overvoltage shutdown H X 0001 XXXX OFF X L one SC shutdown H L0001 X 0 0 X OFF OFF L one SC shutdown, with other off & normal H H 0001 X 000 OFF ON L one SC shutdown, with other on & normal H X 00001 X X X OFF X L one OT shutdown H L0000100 X OFF OFF L one OT shutdown, with other off & normal H H 00001000 OFF ON L one OT shutdown, with other on & normal |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |