| 数据搜索系统,热门电子元器件搜索 |
|
CP10.242-R2 数据表(PDF) 17 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP10.242-R2 数据表(HTML) 17 Page - PULS GmbH |
|
17 / 31 page ![]() CP10.241-R1, CP10.241-R2, CP10.241-R3,CP10.242-R2 CP-Series 24V, 10A, 240W, SINGLE PHASE Feb. 2018 / CP10.241-R2 Rev0.3-EN - All values are typical figures specified at 230Vac, 50Hz input voltage, 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 17/31 P R E L I M I N A R Y 16. EMC The EMC behavior of the device is designed for applications in industrial environment as well as in residential, commercial and light industry environments. EMC Immunity According to the generic standards EN 61000-6-1 and EN 61000-6-2 Electrostatic discharge EN 61000-4-2 Contact discharge Air discharge 8kV 15kV Criterion A Criterion A Electromagnetic RF field EN 61000-4-3 80MHz-2.7GHz 20V/m Criterion A Fast transients (Burst) EN 61000-4-4 Input lines Output lines DC-OK signal (coupling clamp) 4kV 2kV 2kV Criterion A Criterion A Criterion A Surge voltage on input EN 61000-4-5 L N L PE, N PE 2kV 4kV Criterion A Criterion A Surge voltage on output EN 61000-4-5 + - + / - PE 1kV 2kV Criterion A Criterion A Surge voltage on Signals EN 61000-4-5 DC-OK signal PE 1kV Criterion A Conducted disturbance EN 61000-4-6 0.15-80MHz 20V Criterion A Mains voltage dips EN 61000-4-11 0% of 100Vac 40% of 100Vac 70% of 100Vac 0% of 200Vac 40% of 200Vac 70% of 200Vac 0Vac, 20ms 40Vac, 200ms 70Vac, 500ms 0Vac, 20ms 80Vac, 200ms 140Vac, 500ms Criterion A Criterion C Criterion A Criterion A Criterion A Criterion A Voltage interruptions EN 61000-4-11 0% of 200Vac (=0V) 5000ms Criterion C Voltage sags SEMI F47 0706 Dips on the input voltage according to SEMI F47 standard 80% of 120Vac (96Vac) 70% of 120Vac (84Vac) 50% of 120Vac (60Vac) 1000ms 500ms 200ms Criterion A Criterion A Criterion A Powerful transients VDE 0160 Over entire load range 750V, 0.3ms Criterion A Criterions: A: Power supply shows normal operation behavior within the defined limits. C: Temporary loss of function is possible. Device may shut-down and restarts by itself. No damage or hazards for the power supply will occur. EMC Emission According to the generic standards EN 61000-6-3 and EN 61000-6-4 Conducted emission input lines EN 55011, EN 55015, EN 55022, FCC Part 15, CISPR 11, CISPR 22 Class B Conducted emission output lines IEC/CISPR 16-1-2, IEC/CISPR 16-2-1 Limits for DC power ports according to EN 61000-6-3 are fulfilled Radiated emission EN 55011, EN 55022 Class B Harmonic input current EN 61000-3-2 Class A fulfilled between 0A and 12A load Class C fulfilled between 6A and 12A load Voltage fluctuations, flicker EN 61000-3-3 Fulfilled, tested with constant current loads, non pulsing This device complies with FCC Part 15 rules. Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Switching Frequencies PFC converter 100kHz Fixed frequency Main converter 84-140kHz Output load dependent Auxiliary converter 60kHz Fixed frequency |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |