28 / 31 page ![]() CP10.241-R1, CP10.241-R2, CP10.241-R3,CP10.242-R2 CP-Series 24V, 10A, 240W, SINGLE PHASE Feb. 2018 / CP10.241-R2 Rev0.3-EN - All values are typical figures specified at 230Vac, 50Hz input voltage, 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 28/31 P R E L I M I N A R Y 24.5. SERIES OPERATION Power supplies of the same type can be connected in series for higher output voltages. It is possible to connect as many units in series as needed, providing the sum of the output voltage does not exceed 150Vdc. Voltages with a potential above 60Vdc must be installed with a protection against touching. Unit A Input Output Unit B - + - + Load + - Input Output Avoid return voltage (e.g. from a decelerating motor or battery) which is applied to the output terminals. Keep an installation clearance of 15mm (left / right) between two power supplies and avoid installing the power supplies on top of each other. Do not use power supplies in series in mounting orientations other than the standard mounting orientation (input terminals on bottom of the unit). Pay attention that leakage current, EMI, inrush current, harmonics will increase when using multiple power supplies. 24.6. PARALLEL USE TO INCREASE OUTPUT POWER Power supplies can be paralleled to increase the output power. For redundancy applications one extra power supply is always needed for sufficient output current in case one unit fails. Unit A Unit B - + - + Load + - Input Output Input Output The unit is permanently set to “parallel use” mode in order to achieve load sharing between power supplies connected in parallel. The “Parallel use” mode regulates the output voltage in such a manner that the voltage at no load is approx. 4% higher than at nominal load. See also chapter 6. Energize all units at the same time. It also might be necessary to cycle the input power (turn-off for at least five seconds), if the output was in overload or short circuits and the required output current is higher than the current of one unit. Keep an installation clearance of 15mm (left / right) between two power supplies and avoid installing the power supplies on top of each other. Do not use power supplies in parallel in mounting orientations other than the standard mounting orientation (input terminals on bottom of the unit) or in any other condition where a derating of the output current is required (e.g. altitude). Pay attention that leakage current, EMI, inrush current, harmonics will increase when using multiple power supplies. Do not load paralleled power supplies with higher currents as shown in the following diagrams: Fig. 24-6 Output current vs. ambient temp. for two paralleled units Fig. 24-7 Output current vs. ambient temp. for three paralleled units Allowed output current for two paralleled units Allowed output current for three paralleled units 24A 0 30 40 50 60 70°C 4A 8A 12A 16A 20A B 36A A Ambient Temperature A... continuous B... short term (max. 5s) 36.6 14A 0 30 40 50 60 70°C 6A 12A 18A 24A 30A B A 21A A... continuous B... short term (max. 5s) 36.6 Ambient Temperature |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |