| 数据搜索系统,热门电子元器件搜索 |
|
CP20.241-R1 数据表(PDF) 13 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP20.241-R1 数据表(HTML) 13 Page - PULS GmbH |
|
13 / 33 page ![]() CP20.241-R1, CP20.241-R2, CP20.241-R3, CP20.242-R2, CP20.242-R2-C1 CP-Series 24V, 20A, 480W, SINGLE PHASE Jan. 2018 / Rev. 0.2 DS-CP20.241-R2-EN - All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 20A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 13/33 P R E L I M I N A R Y 10. LIFETIME EXPECTANCY The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years (131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices. AC 100V AC 120V AC 230V Lifetime expectancy 117 000h 136 000h 164 000h At 10A and 40°C 331 000h 386 000h 465 000h At 10A and 25°C 40 000h 53 000h 90 000h At 20A and 40°C 114 000h 150 000h 253 000h At 20A and 25°C 16 000h 25 000h 47 000h At 24A and 40°C 44 000h 69 000h 134 000h At 24A and 25°C 11. MTBF MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it can not be determined if the failed unit has been running for 50 000h or only for 100h. For these types of units the MTTF (Mean Time To Failure) value is the same value as the MTBF value. AC 100V AC 120V AC 230V MTBF SN 29500, IEC 61709 387 000h 412 000h 543 000h At 20A and 40°C 723 000h 768 000h 976 000h At 20A and 25°C MTBF MIL HDBK 217F 164 000h 169 000h 199 000h At 20A and 40°C; Ground Benign GB40 224 000h 231 000h 272 000h At 20A and 25°C; Ground Benign GB25 34 000h 36 000h 42 000h At 20A and 40°C; Ground Fixed GF40 45 000h 47 000h 56 000h At 20A and 25°C; Ground Fixed GF25 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |