27 / 33 page ![]() CP20.241-R1, CP20.241-R2, CP20.241-R3, CP20.242-R2, CP20.242-R2-C1 CP-Series 24V, 20A, 480W, SINGLE PHASE Jan. 2018 / Rev. 0.2 DS-CP20.241-R2-EN - All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 20A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 27/33 P R E L I M I N A R Y 24. APPLICATION NOTES 24.1. PEAK CURRENT CAPABILITY The unit can deliver peak currents (up to several milliseconds) which are higher than the specified short term currents. This helps to start current demanding loads. Solenoids, contactors and pneumatic modules often have a steady state coil and a pick-up coil. The inrush current demand of the pick-up coil is several times higher than the steady-state current and usually exceeds the nominal output current (including the PowerBoost). The same situation applies when starting a capacitive load. The peak current capability also ensures the safe operation of subsequent circuit breakers of load circuits. The load branches are often individually protected with circuit breakers or fuses. In case of a short or an overload in one branch circuit, the fuse or circuit breaker need a certain amount of over-current to open in a timely manner. This avoids voltage loss in adjacent circuits. The extra current (peak current) is supplied by the power converter and the built-in large sized output capacitors of the power supply. The capacitors get discharged during such an event, which causes a voltage dip on the output. The following three examples show typical voltage dips for resistive loads: Fig. 24-1 40A peak current for 50ms, typ. (2x the nominal current) Fig. 24-2 100A peak current for 5ms, typ. (5x the nominal current) 10ms/DIV Output Voltage Output Current 24V 0A 40A 16V 24V Output Voltage Output Current 1ms/DIV 0A 100A 16.5V Fig. 24-3 60A peak current for 12ms, typ. (3x the nominal current) 24V 20V 0A 12ms 60A Output Voltage Output Current Please note: The DC-OK relay might triggers when the voltage dips below 22Vdc for longer than 1ms. Peak current voltage dips typ. from 24V to 16V At 40A for 50ms, resistive load typ. from 24V to 21V At 100A for 2ms, resistive load typ. from 24V to 16.5V At 100A for 5ms, resistive load |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |