| 数据搜索系统,热门电子元器件搜索 |
|
CP20.241-R2 数据表(PDF) 21 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP20.241-R2 数据表(HTML) 21 Page - PULS GmbH |
|
21 / 33 page ![]() CP20.241-R1, CP20.241-R2, CP20.241-R3, CP20.242-R2, CP20.242-R2-C1 CP-Series 24V, 20A, 480W, SINGLE PHASE Jan. 2018 / Rev. 0.2 DS-CP20.241-R2-EN - All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 20A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 21/33 P R E L I M I N A R Y 18. SAFETY AND PROTECTION FEATURES Isolation resistance Min. 500MOhm At delivered condition between input and output, measured with 500Vdc Min. 500MOhm At delivered condition between input and PE, measured with 500Vdc Min. 500MOhm At delivered condition between output and PE, measured with 500Vdc Min. 500MOhm At delivered condition between output and DC-OK contacts, measured with 500Vdc PE resistance Max. 0.1Ohm Resistance between PE terminal and the housing in the area of the DIN-rail mounting bracket. Output over-voltage protection Typ. 30.5Vdc Max. 32Vdc In case of an internal defect, a redundant circuit limits the maximum output voltage. The output shuts down and automatically attempts to restart. Class of protection I According to IEC 61140 A PE (Protective Earth) connection is required Degree of protection IP 20 According to EN/IEC 60529 Over-temperature protection Included Output shut-down with automatic restart. Temperature sensors are installed on critical components inside the unit and turn the unit off in safety critical situations, which can happen e.g. when ambient temperature is too high, ventilation is obstructed or the de-rating requirements are not followed. There is no correlation between the operating temperature and turn-off temperature since this is dependent on input voltage, load and installation methods. Input transient protection MOV (Metal Oxide Varistor) For protection values see chapter 16 (EMC). Internal input fuse Included Not user replaceable slow-blow high-braking capacity fuse Touch current (leakage current) Typ. 0.12mA / 0.31mA At 100Vac, 50Hz, TN-,TT-mains / IT-mains Typ. 0.18mA / 0.45mA At 120Vac, 60Hz, TN-,TT-mains / IT-mains Typ. 0.30mA / 0.76mA At 230Vac, 50Hz, TN-,TT-mains / IT-mains Max. 0.16mA / 0.38mA At 110Vac, 50Hz, TN-,TT-mains / IT-mains Max. 0.23mA / 0.55mA At 132Vac, 60Hz, TN-,TT-mains / IT-mains Max. 0.39mA / 0.94mA At 264Vac, 50Hz, TN-,TT-mains / IT-mains Penetration protection Max. 5mm in diameter E.g. screws, small parts |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |