| 数据搜索系统,热门电子元器件搜索 |
|
MAS6510 数据表(PDF) 25 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS6510 数据表(HTML) 25 Page - Micro Analog systems |
|
25 / 32 page ![]() DA6510.009 6 September, 2018 25 (32) TRIMMING FOR SENSOR CAPACITANCE (continued) MAS6510 in capacitance ratio mode Optimal trim settings which adjust capacitive signal to linear conversion range 10%...90% of the CDC are found as follows. COFS = [0.9*CS_EXT_MAX*(CS_EXT_MIN – CR_EXT_MAX) – 0.1*CS_EXT_MIN *(CS_EXT_MAX - CR_EXT_MIN)] / [0.9*CS_EXT_MAX - 0.1*CS_EXT_MIN] Equation 16. If COFS ≥ 0pF then CR_INT = COFS and CS_INT = 0pF else CR_INT = 0pF and CS_INT is calculated as follows. a = 0.8 b = 0.9*(CS_EXT_MAX + CS_EXT_MIN – CR_EXT_MAX) – 0.1*(CS_EXT_MAX + CS_EXT_MIN - CR_EXT_MIN) Equation 17a. c = 0.9*CS_EXT_MAX *(CS_EXT_MIN – CR_EXT_MAX) – 0.1*CS_EXT_MIN *(CS_EXT_MAX - CR_EXT_MIN) Equation 17b. CS_INT1 = [-b+ (b^2-4*a*c)]/2/a Equation 17c. CS_INT2 = [-b- (b^2-4*a*c)]/2/a Equation 17d. If CS_INT1 ≥ 0pF then CS_INT = CS_INT1 else CS_INT= CS_INT2 If CR_EXT does not exist (CR_EXT = 0pF) the equation 16 simplifies to following form. COFS = CR_INT = 0.8*CS_EXT_MAX*CS_EXT_MIN / (0.9*CS_EXT_MAX - 0.1*CS_EXT_MIN) Equation 18. Corresponding capacitance matrix register (REGE3HEX and REGE4HEX) values (decimal) are calculated using equations 12 and 13 presented on page 24. Optimal gain coefficient (KRATIO) value is calculated as follows. KRATIO = 0.1 * (CS_EXT_MIN + CS_INT) / (CS_EXT_MIN + CS_INT – CR_EXT_MAX - CR_INT) = Equation 19a. = 0.9 * (CS_EXT_MAX + CS_INT) / (CS_EXT_MAX + CS_INT – CR_EXT_MIN - CR_INT) Equation 19b. Corresponding Gain register (REGE5HEX) value (decimal) can be solved from the equation 10 presented on page 23 as follows. GRDAC = 193.8/ KRATIO (see table 6 for Gain register setting) Equation 20. Example 1: Only CS_EXT varies and CR_EXT does not exist (CR_EXT = 0pF) CS_EXT_MIN=4pF at sensed parameter (pressure, humidity etc.) minimum CS_EXT_MAX=12pF at sensed parameter (pressure, humidity etc.) maximum CR_EXT_MIN/MAX = 0pF (no external reference capacitor) COFS = 0.8*12pF*4pF/(0.9*12pF-0.1*4pF) = 3.69pF ≥ 0 CR_INT = COFS = 3.69pF and CS_INT = 0pF KRATIO = 0.1*(4pF+0pF)/(4pF-0pF-0pF-3.69pF) = 1.3 REGE3HEX = OCDACS = (0pF/22pF)*255 = 0DEC (CS capacitor matrix) REGE4HEX = OCDACR = (3.69pF/22pF)*255 43DEC (CR capacitor matrix) REGE5HEX = GRDAC = 193.8/1.3 = 149.08 149DEC (Gain register) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |