5 / 23 page ![]() Philips Semiconductors Product data sheet SA56004X ±1 °C accurate, SMBus-compatible, 8-pin, remote/local digital temperature sensor with over temperature alarms 2004 Oct 06 5 ELECTRICAL CHARACTERISTICS Tamb = 0 °C to +125 °C, VDD = 3.0 V to 3.6 V, unless otherwise specified. SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT TERRL Local temperature error Tamb = 60 °C to +100 °C –2 ±1 +2 °C Tamb = 0 °C to +125 °C –3 – +3 °C TERRR Remote temperature error Tamb = +25 °C to +85 °C; TRD = +60 °C to +100 °C –1 – +1 °C Tamb = 0 °C to +85 °C; TRD = 0 °C to +125 °C –3 – +3 °C TRESR Remote temperature resolution – 11 – bits – 0.125 – °C TRESL Local temperature resolution – 11 – bits – 0.125 – °C tCONV Conversion time – 38 – ms VDD Supply voltage1 3.0 – 5.5 V IDD Quiescent current During conversion, 16 Hz conversion rate – 500 – µA Shutdown current SMBus inactive – 10 – µA IRD Remote diode source current High setting: D+ – D– = +0.65 V – 160 – µA Low setting – 10 – µA UVL Undervoltage lockout (UVL) threshold voltage2 VDD input disables A/D conversion3 2.6 – 2.95 V Power-on-Reset (POR) threshold voltage VDD, input falling edge4 1.8 – 2.4 V Local and Remote ALERT HIGH default temperature settings Default values set at power-up – +70 – °C Local and Remote ALERT LOW default temperature settings Default values set at power-up – 0 – °C Local and Remote T_CRIT default temperature settings Default values set at power-up – +85 – °C Hystersis (T_CRIT) Default value set at power-up – +10 – °C ALERT and T_CRIT output saturation voltage IOUT = 6.0 mA – – 0.4 V NOTES: 1. The SA56004X is optimized for 3.3 VDD operation. 2. Definition of Under Voltage Lockout (UVL): The value of VDD below which the internal A/D converter is disabled. This is designed to be a minimum of 200 mV above the power-on-reset. During the time that it is disabled, the temperature that is in the “read temperature registers” will remain at the value that it was before the A/D was disabled. This is done to eliminate the possibility of reading unexpected false temperatures due to the A/D converter not working correctly due to low voltage. In case of power-up (rising VDD), the reading that is stored in the “read temperature registers” will be the default value of 0 °C. VDD will rise to the value of the UVL, at which point the A/D will function correctly and the normal temperature will be read. 3. VDD (rising edge) voltage below which the A/D converter is disabled. 4. VDD (falling edge) voltage below which the logic is reset. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |