16 / 23 page ![]() Philips Semiconductors Product data sheet SA56004X ±1 °C accurate, SMBus-compatible, 8-pin, remote/local digital temperature sensor with over temperature alarms 2004 Oct 06 16 T_CRIT output The T_CRIT output is LOW when any temperature reading is greater than the preset limit in the corresponding critical temperature setpoint register. When one of the T_CRIT setpoint temperatures is exceeded, the appropriate status register bit, 1 (RCRIT) or 0 (LCRIT), is set. After every local and remote temperature conversion the Status register flags and the T_CRIT output are updated. Figure 15 is a timing diagram showing the relationship of T_CRIT output, Status bit 1 (RCRIT) and the remote critical temperature setpoint (RCS), and critical temperature hysteresis (TH) with remote temperature changes. Note that the T_CRIT output is de-activated only after the remote temperature is below the remote temperature setpoint, RCS minus the Hysteresis, TH. In the interrupt mode only, the Status register flags are reset after the Status register is read. RCS RCS - TH Status Bit 1, RCRIT T_CRIT Output Remote Temperature A BC SL02058 Figure 15. T_CRIT temperature response timing diagram Event A: T_CRIT goes LOW and Status bit 1, RCRIT is set HIGH when Remote Temperature exceeds RCS, Remote T_CRIT Setpoint. Event B: Remote Temperature goes below RCS-TH. T_CRIT is deactivated, but Status Register remains unchanged. Event C: The Status Register Bit 1, RCRIT is reset by a read of the Status Register (in the interrupt mode). Fault Queue To suppress erroneous ALERT or T_CRIT triggering, the SA56004X implements a Fault Queue for both local and remote channel. The Fault Queue insures a temperature measurement is genuinely beyond a HIGH, LOW or T_CRIT setpoint by not triggering until three consecutive out-of-limit measurements have been made. The fault queue defaults off upon POR and may be activated by setting bit 0 in the Configuration register (address 09h) to ‘1’. Remote HIGH Setpoint Remote LOW Setpoint RCS ALERT Output RCS -TH Remote Temperature T_CRIT Output AB C DE F G H Events I SL02059 NOTE: All events indicate the completion of a conversion. Figure 16. Fault Queue Remote High and Low and T_CRIT, T_CRIT Hysteresis setpoint response (Comparator mode) At Event A: The remote temperature has exceeded the Remote HIGH setpoint. At Event B: Three consecutive over limit measurements have been made exceeding the Remote HIGH setpoint; the ALERT output is activated (goes LOW). By now, the remote temp has exceeded the Remote T_CRIT setpoint (RCS). At Event C: Three consecutive over limit measurements have been made exceeding RCS; the T_CRIT output is activated (goes LOW). At Event D: The remote temperature falls below the RCS–TH setpoint. At Event E: The ALERT output is de-activated (goes HIGH) after a below_high_limit temperature measurement is completed. At Event F: Three consecutive measurements have been made with the remote temperature below the RCS–TH threshold; the T_CRIT output is de-activated (goes HIGH). At Event G: The remote temp falls below the Remote LOW setpoint. At Event H: Three consecutive measurements are made with the temp below the Remote LOW setpoint; ALERT output is activated (goes LOW). At Event I: The ALERT output is de-activated (goes HIGH) after a above_low_limit temperature measurement is completed. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |