14 / 23 page ![]() Philips Semiconductors Product data sheet SA56004X ±1 °C accurate, SMBus-compatible, 8-pin, remote/local digital temperature sensor with over temperature alarms 2004 Oct 06 14 Programmable offset register (remote only) Table 12. Remote Temperature Offset registers (RTOHB and RTOLB) High Byte (Read/Write address 11h) Bit D7 D6 D5 D4 D3 D2 D1 D0 Value Sign 64 32 16 8 4 2 1 POR default RTOHB = RTOLB = 00h. Low Byte (Read/Write address 12h) Bit D7 D6 D5 D4 D3 D2 D1 D0 Value 0.5 0.25 0.125 0 0 0 0 0 POR default RTOLB = 00h. ALERT mode register Table 13. ALERT mode register (AM) (Read and Write address BFh) Bit D7 D6 D5 D4 D3 D2 D1 D0 Value 0 0 0 0 0 0 0 ALERT mode D7-D1: is not defined and defaults to ‘0’. D0: The ALERT output is in Interrupt mode when this bit is LOW. The ALERT output is in comparator mode when this bit is HIGH. Other registers The Manufacturers ID register has a default value A1h (1010 0001) and a read address FEh. The Die Revision Code register has a default value 00h (0000 0000) and read address FFh. This register will increment by 1 every time there is a revision to the die. One-shot register The one-shot register is used to initiate a single conversion and comparison cycle when the device is in the standby mode; upon completion of the single conversion cycle the device returns to the standby mode. It is not a data register; it is the write operation that causes the one-shot conversion. The data written to this register is not stored; a FF value will always be read from this register. To initiate an one-shot operation, send a standard write command with the command byte of 0Fh (One-Shot Write Address). INTERRUPTION LOGIC FUNCTIONAL DESCRIPTION ALERT output The ALERT output is used to signal Alert interruptions from the device to the SMBus or other system interrupt handler and it is active LOW. Because this is an open drain output, a pull-up resistor (typically 10 k Ω) to VDD is required. Several slave devices can share a common interrupt line on the same SMBus. The ALERT function is very versatile and accommodates three separate operating modes: 1) a temperature comparator, 2) a system interrupt based on temperature, and 3) an SMBus Alert Response Address (ARA) response. The ARA and interrupt modes are different only in how the user interacts with the SA56004X. At the end of every temperature reading, digital comparators determine if the readings are above the HIGH or T_CRIT setpoint or below the LOW setpoint register values. If so, the corresponding bit in the Status register is set. If the ALERT mask bit 7 of the Configuration register is not HIGH, then, any bit set in the Status register, other than the BUSY (D7) and OPEN (D2), will cause the ALERT output pin to be active-LOW. An alert will be triggered after any conversion cycle that finds the temperature is out of the limits defined by the setpoint registers. In order to trigger an ALERT in all alert modes, the ALERT mask bit 7 of the Configuration register must be cleared (not HIGH). ALERT output in Comparator Mode When operating the SA56004X in a system that utilizes a SMBus controller not having an interrupt, the ALERT output may be operated as a temperature comparator. In this mode, when the condition that triggered the ALERT to be asserted is no longer present, the ALERT output is released as it goes HIGH. In order to use the ALERT output as a temperature comparator, bit D0, the ALERT configure bit, in the ALERT Mode (AM) register must be set HIGH. This is not the POR default. ALERT output in Interrupt Mode In the interrupt mode, the ALERT output is used to provide an interrupt signal that remains asserted until the interrupt service routine has elapsed. In the interrupt operating mode, a read of the Status register will set the ALERT mask bit 7 of the Configuration register if any of the temperature alarm bits of the status register is set with exception of BUSY (D7) and OPEN (D2). This protocol prevents further ALERT output triggering until the master device has reset the ALERT mask bit at the end of the interrupt service routine. The Status register bits are cleared only upon a read of the status register by the serial bus master (See Figure 13). In order for the ALERT output to be used as an interrupt, the ALERT Configure bit D0 of the ALERT Mode (AM) register must be set LOW. Note, this is the POR default. Remote Temp High Limit SA56004–X Status Register Bit 4(RHIGH) Remote Diode Temp A B,C D ALERT pin SR02502 E, F Figure 13. ALERT output in Interrupt Mode The following events summarizes the ALERT output interrupt mode of operation: Event A: Master senses ALERT output being active-LOW. Event B: Master reads the SA56004X Status register to determine what cause the ALERT interrupt. Event C: SA56004X clears the Status register, resets the ALERT output HIGH, and sets the ALERT mask bit 7 in the Configuration register. Event D: A new conversion result indicates the temperature is still above the high limit, however the ALERT pin is not activated due to the ALERT mask. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |