| 数据搜索系统,热门电子元器件搜索 |
|
ADP1074WARWZ-R7 数据表(PDF) 8 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1074WARWZ-R7 数据表(HTML) 8 Page - Analog Devices |
|
8 / 32 page ![]() ADP1074 Data Sheet Rev. D | Page 8 of 32 REGULATORY INFORMATION See Table 4, Table 5, and the Insulation Lifetime section for details regarding recommended maximum working voltages for specific cross isolation waveforms and insulation levels. Table 4. Regulatory Information for Wide Body SOIC Package UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending) Recognized Under UL 1577 Component Recognition Program1 Approved under CSA Component Acceptance Notice 5A Certified according to DIN V VDE V 0884-10 (VDE V 0884-10):2006-122 Certified by CQC11-471543-2012, GB4943.1-2011: Single Protection, 5000 V rms Isolation Voltage CSA 60950-1-07+A1+A2 and IEC 60950-1, second edition, +A1+A2 and IEC62368: Reinforced insulation, maximum working insulation voltage (VIORM) = 849 V peak, highest allowable overvoltage (VIOTM) = 8000 V peak Basic insulation at 780 V rms (1103 V peak) Basic insulation at 780 V rms (1103 V peak) Reinforced insulation at 389 V rms (552 V peak), tropical climate, altitude ≤5000 meters Reinforced insulation at 390 V rms (552 V peak) IEC 60601-1 Edition 3.1: Basic insulation (1 means of patient protection (1 MOPP)), 490 V rms (686 V peak) Reinforced insulation (2 MOPP), 238 V rms (325 V peak) CSA 61010-1-12 and IEC 61010-1 third edition: Basic insulation at 300 V rms mains, 780 V secondary (1103 V peak) File (pending) File (pending) File (pending) File (pending) 1 In accordance with UL 1577, each product is proof tested by applying an insulation test voltage ≥6000 V rms for 1 sec. 2 In accordance with DIN V VDE V 0884-10, each product is proof tested by applying an insulation test voltage ≥1592 V peak for 1 sec (partial discharge detection limit = 5 pC). Note that the asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval. Table 5. Regulatory Information for LGA Package UL (Pending) CSA (Pending) VDE (Pending) CQC (Pending) Recognized Under UL 1577 Component Recognition Program1 Approved under CSA Component Acceptance Notice 5A Certified according to DIN V VDE V 0884-10 (VDE V 0884-10):2006-122 Certified by CQC11-471543-2012, GB4943.1-2011: Single Protection, 3000V rms Isolation Voltage CSA 60950-1-07+A1+A2 and IEC 60950-1, second edition, +A1+A2 and IEC62368: Reinforced insulation, VIORM = 565 V peak, VIOTM = 4242 V peak impulse voltage = 4242 V peak Basic insulation at 400 V rms (565 V peak) Basic insulation at 400 V rms (565 V peak) Reinforced insulation at 200 V rms (283 V peak), tropical climate, altitude ≤5000 meters Reinforced insulation at 200 V rms (283 V peak) IEC 60601-1 Edition 3.1: Basic insulation (1 means of patient protection (1 MOPP)), 250 V rms (354 V peak) CSA 61010-1-12 and IEC 61010-1 third edition: Basic insulation at 300 V rms mains, 400 V secondary (565 V peak) File (pending) File (pending) File (pending) File (pending) 1 In accordance with UL 1577, each product is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec. 2 In accordance with DIN V VDE V 0884-10, each product is proof tested by applying an insulation test voltage ≥1059 V peak for 1 sec (partial discharge detection limit = 5 pC). Note that the asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |